1910.1047(g) Respiratory Protection and Personal Protective Equipment
Go To Full Code Chapter
1910.1047(g)(1) General
For employees who use respirators required by this section, the employer must provide each employee an appropriate respirator that complies with the requirements of this paragraph. Respirators must be used during:
1910.1047(g)(1)(i)
Periods necessary to install or implement feasible engineering and work-practice controls.
1910.1047(g)(1)(iii)
Work operations for which feasible engineering and work-practice controls are not yet sufficient to reduce employee exposure to or below the TWA.
1910.1047(g)(1)(iv) Emergencies
1910.1047(g)(1)(ii)
Work operations, such as maintenance and repair activities and vessel cleaning, for which engineering and work-practice controls are not feasible.
1910.1047(g)(2) Respirator Program
The employer must implement a respiratory protection program in accordance with § 1910.134(b) through (d) (except (d)(i)(iii)), and (f) through (m), which covers each employee required by this section to use a respirator.
1910.1047(g)(3) Respirator Selection
Employers must:
1910.1047(g)(3)(i)
Select, and provide to employees, the appropriate respirators specified in paragraph (d)(3)(i)(A) of 29 CFR 1910.134; however, employers must not select or use half masks of any type because EtO may cause eye irritation or injury.
1910.1047(g)(3)(iii)
For escape, provide employees with any respirator permitted for use under paragraphs (g)(3)(i) and (ii) of this standard.
1910.1047(g)(3)(ii)
Equip each air-purifying, full facepiece respirator with a front-or back-mounted canister approved for protection against ethylene oxide.
1910.1047(g)(4) Protective Clothing and Equipment
When employees could have eye or skin contact with EtO or EtO solutions, the employer must select and provide, at no cost to the employee, appropriate protective clothing or other equipment in accordance with 29 CFR 1910.132 and 1910.133 to protect any area of the employee's body that may come in contact with the EtO or EtO solution, and must ensure that the employee wears the protective clothing and equipment provided.
Upcodes Diagrams
Related Code Sections
1910.1047(g) Toxic and Hazardous Substances, Respiratory Protection and Personal Protective Equipment
The employer must implement a respiratory protection program in accordance with § 1910.134(b) through (d ...
1910.1047(g)(1)(ii) Toxic and Hazardous Substances,
Work operations, such as maintenance and repair activities and vessel cleaning, for which engineering and work-practice controls are not feasible ...
1910.1047(g)(1)(iii) Toxic and Hazardous Substances,
Work operations for which feasible engineering and work-practice controls are not yet sufficient to reduce employee exposure to or below the TWA ...
1910.1047(g)(3)(ii) Toxic and Hazardous Substances,
Equip each air-purifying, full facepiece respirator with a front-or back-mounted canister approved for protection against ethylene oxide ...