1910.134(d)(2) Respirators for IDLH Atmospheres
Go To Full Code Chapter
1910.134(d)(2)(i)
The employer shall provide the following respirators for employee use in IDLH atmospheres:
1910.134(d)(2)(i)(A)
A full facepiece pressure demand SCBA certified by NIOSH for a minimum service life of thirty minutes, or
1910.134(d)(2)(i)(B)
A combination full facepiece pressure demand supplied-air respirator (SAR) with auxiliary self-contained air supply.
1910.134(d)(2)(iii)
All oxygen-deficient atmospheres shall be considered IDLH. Exception: If the employer demonstrates that, under all foreseeable conditions, the oxygen concentration can be maintained within the ranges specified in Table II of this section (i.e., for the altitudes set out in the table), then any atmosphere-supplying respirator may be used.
1910.134(d)(2)(ii)
Respirators provided only for escape from IDLH atmospheres shall be NIOSH-certified for escape from the atmosphere in which they will be used.
Upcodes Diagrams
Related Code Sections
1910.134(d)(2) Personal Protective Equipment, Respirators for IDLH Atmospheres
The employer shall provide the following respirators for employee use in IDLH atmospheres ...
1910.134(g)(3)(ii) Personal Protective Equipment,
Visual, voice, or signal line communication is maintained between the employee(s) in the IDLH atmosphere and the employee(s) located outside the IDLH ...
1910.134(g)(3)(iv) Personal Protective Equipment,
The employer or designee is notified before the employee(s) located outside the IDLH atmosphere enter the IDLH atmosphere to provide emergency rescue; ...
1910.134(g)(3)(i) Personal Protective Equipment,
One employee or, when needed, more than one employee is located outside the IDLH atmosphere; ...
1910.134(g)(3)(iii) Personal Protective Equipment,
The employee(s) located outside the IDLH atmosphere are trained and equipped to provide effective emergency rescue; ...