• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1027.4 Residential Building Hallway Corridor and Elevator Lobby Furnishings, Decorations and Storage

NYC Fire Code 2014 > 10 Means of Egress > 1027 Maintenance of the Means of Egress > 1027.4 Residential Building Hallway Corridor and Elevator Lobby Furnishings, Decorations and Storage
JUMP TO FULL CODE CHAPTER
This section governs the placement of furnishings and decorations, and storage of combustible materials in building hallway corridors (excluding hallways within dwelling units) and in elevator lobbies above the street level, in Group R-2 buildings and occupancies. The department may by rule prohibit any type of building hallway corridor or elevator lobby furnishing, decoration or storage allowed by this section, or by order direct removal from a particular premises of any such furnishing, decoration or stored item, upon a determination that the size, materials or location of such furnishing, decoration or stored item presents an undue fire hazard.

1027.4.1 Incidental Furnishings

A building hallway corridor or elevator lobby may be furnished with a console table, console bench, mirror, and umbrella stand, provided that the minimum required egress width is maintained. All such furnishings must be incidental to hallway use in that the purpose of such furnishings is primarily decorative and/or for the convenience of persons passing through the hallways. Incidental furnishings shall not include furniture used to hold or store clothing or other combustible items, or storage in the hallway of furniture, such as beds and dining room tables, whose primary purpose is not decorative or for the temporary accommodation of passersby.

1027.4.2 Draperies, Area Rugs and Decorative Greens

Draperies, area rugs and decorative greens shall be installed and maintained in building hallway corridors in compliance with the requirements of FC Chapter 8, including the requirement that they be inherently noncombustible or flameproofed by an approved method, and the prohibition against the display in building hallway corridors of Christmas trees and other conifers, and wreathes made of conifers.

1027.4.3 Artwork

The walls of building hallway corridors may be decorated with combustible artwork, including artworks made of paper, canvas, wood or fabric, when in compliance with the requirements of FC805.1.

1027.4.4 Carpeting

Carpeting and other interior finishes shall comply with the requirements of Chapter 8 of the Building Code.

1027.4.5 Personal Property

Bicycles, baby strollers, clothing and other items of personal property, excluding those set forth in FC 1027.4.1 through 1027.4.4, shall not be stored in building hallway corridors, except as may be authorized or allowed by the department.

1027.4.6 Rubbish

Household rubbish, including trash cans, shall not be stored in building hallway corridors. All such items shall be stored in compactor rooms or other lawful storage areas.

Related Code Sections


403.9.1 Special Detailed Requirements Based on Use and Occupancy, Elevator Lobbies
-rated corridor. In all occupancy groups, elevator lobbies shall be provided at any location where an elevator opens onto a fire-resistance rated corridor ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.9 Elevators > 403.9.1 Elevator Lobbies
3008.7.3 Elevators and Conveying Systems, Lobby Doorways
the lobby doorway. The vision panel shall consist of glazing and shall be located to furnish clear vision of the occupant evacuation elevator lobby ...
NYC Building Code 2014 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.7 Occupant Evacuation Elevator Lobby > 3008.7.3 Lobby Doorways
3008.7.3 Elevators and Conveying Systems, Lobby Doorways
protecting the lobby doorway. The vision panel shall consist of glazing and shall be located to furnish clear vision of the occupant evacuation elevator lobby ...
NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3008 Occupant Evacuation Elevators > 3008.7 Occupant Evacuation Elevator Lobby > 3008.7.3 Lobby Doorways
3006.1.1 Elevators and Conveying Systems, Elevator Lobby
Except as provided by Sections 403.6.1 and 403.6.2, an enclosed elevator lobby shall be provided in high-rise buildings at the following locations ...
NYC Building Code 2022 > 30 Elevators and Conveying Systems > 3006 Elevator Lobbies and Hoistway Opening Protection > 3006.1 Elevator, Dumbwaiter and Other Hoistways > 3006.1.1 Elevator Lobby
708.14.1 Fire and Smoke Protection Features, Elevator Lobby
Except as provided by Sections 403.6.1 and 403.6.2, an enclosed elevator lobby shall be provided in high rise buildings at the following locations ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 708 Shaft Enclosures > 708.14 Elevator, Dumbwaiter and Other Hoistways > 708.14.1 Elevator Lobby
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING