All pedestrian circulation space required pursuant to the provisions of any special purpose district shall comply with the provisions of this Section, as such may be modified by the terms of the special district.
37-51 Amount of Pedestrian Circulation Space
The minimum amount of pedestrian circulation space to be provided for developments or enlargements shall be determined by the following table:
MINIMUM PEDESTRIAN CIRCULATION SPACE REQUIREMENTS


Size of zoning lot

Required area of pedestrian circulation space

5,000 to 20,000 sq. ft.

1 sq. ft. per 350 sq. ft. of new floor area

Above 20,000 sq. ft.

1 sq. ft. per 300 sq. ft. of new floor area
37-52 Types of Pedestrian Circulation Space
The pedestrian circulation space provided shall be of one or more of the following types: an arcade, building entrance recess area, corner arcade, corner circulation space, relocation or renovation of a subway stair, sidewalk widening, transit volumes and improvements to mass transit stations, through block connection or public plaza. For the purposes of this Section, defined terms additionally include those in Section 66-11 (Definitions).
Each zoning lot shall be categorized as either a corner lot, through lot or interior lot, and pedestrian circulation space shall be provided on each zoning lot in at least one of the applicable types, or combinations of types, specified in the following table:
PROVISION OF PEDESTRIAN CIRCULATION SPACE  ON CERTAIN TYPES OF LOTS

Type of Pedestrian Circulation Space

Corner lot

Through lot

Interior lot

Arcade

x

x

x

Building entrance recess area

x

x

x

Corner arcade

x





Corner circulation space

x





Relocation or renovation of subway stair

x

x

x

Sidewalk widening

x

x

x

Transit volumes and improvements to mass transit stations

x

x

x

Through block connection

x

x



Public plaza

x

x

x
Minimum design standards for each type of pedestrian circulation space and, where applicable, the maximum amount of each type of pedestrian circulation space that may be counted toward meeting the requirements of Section 37-51 (Amount of Pedestrian Circulation Space) are set forth in Section 37-53 (Design Standards for Pedestrian Circulation Spaces).
See More

Related Code Sections

1104.3 Accessibility, Connected Spaces
, an accessible route shall not be required to serve levels where wheelchair spaces are not provided as permitted by other sections of this chapter. Accessible ...
1104.3 Accessibility, Connected Spaces
by Section 1104.4. In a building, room or space used for assembly purposes with fixed seating, an accessible route shall not be required to serve ...
1104.3 Accessibility, Connected Spaces
route shall not pass through kitchens, storage rooms, restrooms, closets or similar spaces. Exceptions: In assembly areas with seating required ...
610.4 Specific Appliances, Circulating Air
Where a duct furnace is installed so that supply ducts convey air to areas outside the space containing the furnace, the return air shall be conveyed ...