• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.702 Requirements for Equipment and Tools

OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.702 Requirements for Equipment and Tools
JUMP TO FULL CODE CHAPTER

1926.702(a) Bulk Cement Storage

1926.702(a)(1)

Bulk storage bins, containers, and silos shall be equipped with the following:

1926.702(a)(1)(i)

Conical or tapered bottoms; and

1926.702(a)(1)(ii)

Mechanical or pneumatic means of starting the flow of material.

1926.702(a)(2)

No employee shall be permitted to enter storage facilities unless the ejection system has been shut down, locked out, and tagged to indicate that the ejection system is not to be operated.

1926.702(b)

Concrete mixers. Concrete mixers with one cubic yard (-8 m(3)) or larger loading skips shall be equipped with the following:

1926.702(b)(1)

A mechanical device to clear the skip of materials; and

1926.702(b)(2)

Guardrails installed on each side of the skip.

1926.702(c) Power Concrete Trowels

Powered and rotating type concrete troweling machines that are manually guided shall be equipped with a control switch that will automatically shut off the power whenever the hands of the operator are removed from the equipment handles.

1926.702(d) Concrete Buggies

Concrete buggy handles shall not extend beyond the wheels on either side of the buggy.

1926.702(e) Concrete Pumping Systems

1926.702(e)(1)

Concrete pumping systems using discharge pipes shall be provided with pipe supports designed for 100 percent overload.

1926.702(e)(2)

Compressed air hoses used on concrete pumping system shall be provided with positive fail-safe joint connectors to prevent separation of sections when pressurized.

1926.702(f) Concrete Buckets

1926.702(f)(1)

Concrete buckets equipped with hydraulic or pneumatic gates shall have positive safety latches or similar safety devices installed to prevent premature or accidental dumping.

1926.702(f)(2)

Concrete buckets shall be designed to prevent concrete from hanging up on top and the sides.

1926.702(g) Tremies

Sections of tremies and similar concrete conveyances shall be secured with wire rope (or equivalent materials) in addition to the regular couplings or connections.

1926.702(h) Bull Floats

Bull float handles used where they might contact energized electrical conductors, shall be constructed of nonconductive material or insulated with a nonconductive sheath whose electrical and mechanical characteristics provide the equivalent protection of a handle constructed of nonconductive material.

1926.702(i) Masonry Saws

1926.702(i)(1)

Masonry saw shall be guarded with a semicircular enclosure over the blade.

1926.702(i)(2)

A method for retaining blade fragments shall be incorporated in the design of the semicircular enclosure.

1926.702(j) Lockout/Tagout Procedures

1926.702(j)(1)

No employee shall be permitted to perform maintenance or repair activity on equipment (such as compressors mixers, screens or pumps used for concrete and masonry construction activities) where the inadvertent operation of the equipment could occur and cause injury, unless all potentially hazardous energy sources have been locked out and tagged.

1926.702(j)(2)

Tags shall read Do Not Start or similar language to indicate that the equipment is not to be operated.

Related Code Sections


1926.702 Concrete and Masonry Construction, Requirements for Equipment and Tools
Bulk storage bins, containers, and silos shall be equipped with the following ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.702 Requirements for Equipment and Tools
1926.702(b)(2) Concrete and Masonry Construction,
Guardrails installed on each side of the skip ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.702 Requirements for Equipment and Tools > 1926.702(b) > 1926.702(b)(2)
1926.702(d) Concrete and Masonry Construction, Concrete Buggies
Concrete buggy handles shall not extend beyond the wheels on either side of the buggy ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.702 Requirements for Equipment and Tools > 1926.702(d) Concrete Buggies
1926.702(e) Concrete and Masonry Construction, Concrete Pumping Systems
Concrete pumping systems using discharge pipes shall be provided with pipe supports designed for 100 percent overload ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.702 Requirements for Equipment and Tools > 1926.702(e) Concrete Pumping Systems
1926.702(f) Concrete and Masonry Construction, Concrete Buckets
Concrete buckets equipped with hydraulic or pneumatic gates shall have positive safety latches or similar safety devices installed to prevent ...
OSHA 1926 Construction > Q Concrete and Masonry Construction > 1926.702 Requirements for Equipment and Tools > 1926.702(f) Concrete Buckets
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE