26-22 Requirements for Curbs and Curb Cuts
Go To Full Code Chapter
Curbs shall be provided along each side of the entire length of a private road.
A curb cut, excluding splays, from a street to a private road may be as wide as such private road. Curb cuts providing access from private roads to parking spaces located outside the road bed of the private road shall not exceed a width of 18 feet, including splays.
A minimum distance of 16 feet of uninterrupted curb space shall be maintained between all curb cuts.
Related Code Sections
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
For the purpose of this section, a curb cut shall include all splays when determining the total length of cut curb. Unless otherwise required ...
406.7.6 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
For the purpose of this section, a curb cut shall include all splays when determining the total length of cut curb. Unless otherwise required ...
406.10.1 Special Detailed Requirements Based on Use and Occupancy, Curb Cuts
with the following requirements:
The aggregate length of curb cuts shall not exceed 60 percent of any street frontage 100 feet (30 480 mm) or less ...
3202.2.2.4 Encroachments Into the Public Right-of-Way, Curb Cuts
Vehicular access curb cuts that can no longer serve as vehicular access across a curb or sidewalk shall be removed and the curb ...
3202.2.2.4 Encroachments Into the Public Right-of-Way, Curb Cuts
Vehicular access curb cuts that can no longer serve as vehicular access across a curb or sidewalk, including where an existing ...