// CODE SNIPPET
1101.3.1 Requirements Based on Change of Occupancy or How a Space Is Used
JUMP TO FULL CODE CHAPTER
Accessible features and construction governed by this chapter shall be provided:
- To the entire building, as if the building were hereafter erected, where a change is made in the main use or dominant occupancy of such building.
- Throughout a space, including the immediate entrance(s) thereto, where an alteration is made that is considered either (i) a change in occupancy classification of such space in accordance with this code, or (ii) a change in the zoning use group of such space in accordance with the New York City Zoning Resolution.
- Entrances within 18 inches (457.2 mm) of the sidewalk. Where the floor elevation of a space is within 18 inches (457.2 mm) of the sidewalk, and the immediate entrance(s) to such space provides direct access to the sidewalk, such immediate entrance(s) shall be provided with an accessible route to the sidewalk. Where the immediate entrance(s) to such space are only through an adjacent space, such as a building lobby, such space shall be provided with an accessible route, through the adjacent space, to the sidewalk.
- To provide an accessible route to a space, including rooftops, where prior to a change in use of occupancy or in how such space is used, this chapter would not have required an accessible route for new construction.
Related Code Sections
1101.3.1 Accessibility, Requirements Based on Change of Occupancy or How a Space Is Used
erected, where a change is made in the main use or dominant occupancy of such building.
Throughout a space, including the immediate entrance(s ...
NYC Building Code 2014 > 11 Accessibility > 1101 General > 1101.3 Special Provisions for Prior Code Buildings > 1101.3.1 Requirements Based on Change of Occupancy or How a Space Is Used
901.9.2 Fire Protection Systems, Additional Requirements Based on Change of Occupancy or Use
a change is made in the main use or dominant occupancy of such building. Throughout a space, where a change is made in the occupancy group classification ...
NYC Building Code 2014 > 9 Fire Protection Systems > 901 General > 901.9 Special Provisions for Prior Code Buildings > 901.9.2 Additional Requirements Based on Change of Occupancy or Use
416.3 Special Detailed Requirements Based on Use and Occupancy, Spraying Spaces
Spraying spaces shall be ventilated with an exhaust system capable of at least 6 air changes per hour to prevent the accumulation of flammable mist ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 416 Application of Flammable Finishes > 416.3 Spraying Spaces
416.3 Special Detailed Requirements Based on Use and Occupancy, Spraying Spaces
Spraying spaces shall be ventilated with an exhaust system capable of at least six air changes per hour to prevent the accumulation of flammable mist ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 416 Application of Flammable Finishes > 416.3 Spraying Spaces
3202.2.1.4.6 Encroachments Into the Public Right-Of-Way, Change of Occupancy
When the occupancy or use of a building with a marquee is changed to an occupancy or use for which a projecting marquee is not permitted, the marquee ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.1 Encroachments Subject to the Area Limitations > 3202.2.1.4 Marquees > 3202.2.1.4.6 Change of Occupancy