504.4.6 Required Rooftop Clearances
Go To Full Code Chapter
A minimum clearance of 6 feet (1829 mm) in all directions shall be provided from each door opening onto a rooftop from a dwelling unit, stairway, bulkhead, or other occupied space or means of egress, as measured from the door hinge. A minimum clearance of 3 feet (914 mm) in all directions shall be provided from any fire escape or rooftop access ladder, as measured from each side of the ladder or landing.
Related Code Sections
5.6.1.4 Special Application Elevators, Vertical Clearances and Runbys
Bottom and top clearances and runbys for cars and counterweights shall conform to 2.4, except as modified by the following: (a) Table 2.4.2.2 ...
8.6.7.6 General Requirements, Rooftop Elevators
The maintenance of rooftop elevators shall conform to 8.6.1 through 8.6.3 and the applicable requirements of 8.6 ...
8.11.5.10 General Requirements, Rooftop Elevators
Rooftop elevators shall be subject to the applicable periodic inspections specified in 8.11.2 and 8.11.3. The inspection requirements shall apply ...
8.10.5.11 General Requirements, Rooftop Elevators
Rooftop elevators shall be subject to the applicable acceptance inspections and tests specified in 8.10.1 through 8.10.3. The inspection and test ...
Section 1509 Roof Assemblies and Rooftop Structures, Rooftop Structures
limitations and building height requirements of Chapter 5. Rooftop structures shall be constructed with materials as required for the building ...