[P] 2902.3 Required Public Toilet Facilities
JUMP TO FULL CODE CHAPTER
Customers, patrons and visitors shall be provided with public toilet facilities in structures and tenant spaces intended for public utilization. The number of plumbing fixtures located within the required toilet facilities shall be provided in accordance with Section 2902.1 for all users. Employees shall be provided with toilet facilities in all occupancies. Employee toilet facilities shall either be separate or combined employee and public toilet facilities.
The route to the public toilet facilities required by Section 2902.3 shall not pass through kitchens, storage rooms or closets. Access to the required facilities shall be from within the building or from the exterior of the building. All routes shall comply with the accessibility requirements of this code. The public shall have access to the required toilet facilities at all times that the building is occupied.
In occupancies other than covered mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities and the path of travel to such facilities shall not exceed a distance of 500 feet (152 400 mm).
Exception:
The location and maximum travel distances to required employee facilities in factory and industrial occupancies are permitted to exceed that required by this section, provided that the location and maximum travel distance are approved.
In covered mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 300 feet (91 440 mm). In covered mall buildings, the required facilities shall be based on total square footage, and facilities shall be installed in each individual store or in a central toilet area located in accordance with this section. The maximum travel distance to the central toilet facilities in covered mall buildings shall be measured from the main entrance of any store or tenant space. In covered mall buildings, where employees' toilet facilities are not provided in the individual store, the maximum travel distance shall be measured from the employees' work area of the store or tenant space.
Where pay facilities are installed, such facilities shall be in excess of the required minimum facilities. Required facilities shall be free of charge.
Related Code Sections
2902.3 Plumbing Systems, Required Public Toilet Facilities
In occupancies other than covered mall buildings , the required public and employee toilet facilities shall be located ...
Building Code 2009 of Alabama > 29 Plumbing Systems > 2902 Minimum Plumbing Facilities > 2902.3 Required Public Toilet Facilities
403.3 Fixtures, Faucets and Fixture Fittings, Required Public Toilet Facilities
The public shall have access to the required toilet facilities at all times that the building is occupied ...
Plumbing Code 2009 of Alabama > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Public Toilet Facilities
403.3 Fixtures, Faucets and Fixture Fittings, Required Public Toilet Facilities
toilet facilities.
Exception:
Public toilet facilities shall not be required in:
Open or enclosed parking garages where there are no parking ...
Plumbing Code 2015 of Alabama > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Public Toilet Facilities
403.3.4 Fixtures, Faucets and Fixture Fittings, Location of Toilet Facilities in Malls
In covered and open mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below ...
Plumbing Code 2015 of Alabama > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Public Toilet Facilities > 403.3.4 Location of Toilet Facilities in Malls
403.3.1 Fixtures, Faucets and Fixture Fittings, Access
The route to the public toilet facilities required by Section 403.3 shall not pass through kitchens, storage rooms or closets. Access ...
Plumbing Code 2015 of Alabama > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Public Toilet Facilities > 403.3.1 Access