Where load tests are required, at least one test shall be performed in each area of the foundation site within which the subsurface soil conditions are "substantially similar" in character, as determined by the engineer, and at least one test shall be performed for each deep foundation type for the entire foundation installation of the building or group of buildings on a site occupying a total area of 5,000 square feet (464.5 m2) or less. Where load tests are required, at least two load tests shall be performed for a site having a footprint between 5,000 square feet (464.5 m2) and 30,000 square feet (2787.1 m2), and one additional load test shall be performed for each 20,000 square feet (1868,1 m2) of added footprint area. For conditions where multiple deep foundation types or capacities are used, refer to Section 1810.2.5.
1810.4.1.1.1 Additional Load Tests
Where load bearing capacities of the installed deep foundations are in doubt, are considered nonconforming by the engineer, or where required by the commissioner, additional deep foundation elements shall be load tested to establish the allowable capacity. For friction-based deep foundations where the actual production deep foundation lengths vary more than 25 percent from that of the deep foundations initially installed and load tested, the engineer shall determine if additional load tests are required to establish the allowable capacity of the deep foundation. The number of additional load tests shall be determined by the engineer or commissioner.
Upcodes Diagrams

Related Code Sections

1808.4.1.1 Soils and Foundations, Required Number of Load Tests
Where load tests are required, at least one test shall be performed in each area of the foundation site within which the subsurface soil conditions ...
1810.4.1.1 Soils and Foundations, Required Number of Load Tests
Where load tests are required, at least one test shall be performed in each area of the foundation site within which the subsurface soil conditions ...