Carbon monoxide alarms or detectors shall be located within dwelling units as follows:
  1. Outside of any room used for sleeping purposes, within 15 feet (4572 mm) of the entrance to such room.
  2. In any room used for sleeping purposes.
  3. On any story within a dwelling unit, including below-grade stories and penthouses of any area, but not including crawl spaces and uninhabitable attics.