• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

403.3 Required Employee and Public Toilet Facilities

NYC Plumbing Code 2014 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Employee and Public Toilet Facilities
JUMP TO FULL CODE CHAPTER
Employees shall be provided with toilet facilities in all occupancies. The number of plumbing fixtures located within the required employee toilet facilities shall be provided in accordance with Section PC 403 for all employees. Customers, patrons and visitors shall be provided with public toilet facilities in structures and tenant spaces intended for public utilization. The number of plumbing fixtures located within the required public toilet facilities shall be provided in accordance with Section PC 403 for all customers, patrons and visitors. Employee and public toilet facilities may be separate or combined. Where combined facilities are provided, the number of plumbing fixtures shall be in accordance with Section PC 403 for all users.

Exception: Public utilization of toilet facilities shall not be required for:
  1. Food service establishments, as defined in Section 81.03 of the New York City Health Code, with a seating capacity of less than 20, provided such establishments are less than 10,000 square feet (929 m2).
  2. Establishments less than 10,000 square feet (929 m2) classified as Occupancy Group B or M pursuant to Sections 304.1 and 309.1 of the New York City Building Code, respectively, provided however that this exception shall not apply to a building or nonaccessory tenant space used for assembly purposes by fewer than 75 persons and classified as Group B occupancy in accordance with Section 303.1, Exception 2 of the New York City Building Code.

403.3.1 Access

ILLUSTRATION
The route to the public toilet facilities required by Section 403.3 shall not pass through kitchens, storage rooms or closets. Access to the required facilities shall be from within the building or from the exterior of the building. All routes shall comply with the accessibility requirements of the New York City Building Code. Employees, customers, patrons and visitors shall have access to the required toilet facilities at all times that the building is occupied.

403.3.2 Location of Toilet Facilities in Occupancies Other Than Covered Malls

In occupancies other than covered mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 500 feet (152 m).

Exception: The location and maximum travel distances to required employee facilities in factory and industrial occupancies are permitted to exceed that required by this section, provided that the location and maximum travel distance are approved by the department.

403.3.3 Location of Toilet Facilities in Covered Malls

In covered mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 300 feet (91 440 mm). In covered mall buildings, the required facilities shall be based on total square footage, and facilities shall be installed in each individual store or in a central toilet area located in accordance with this section. The maximum travel distance to central toilet facilities in covered mall buildings shall be measured from the main entrance of any store or tenant space. In covered mall buildings, where employees' toilet facilities are not provided in the individual store, the maximum travel distance shall be measured from the employees' work area of the store or tenant space.

403.3.4 Pay Facilities

Where pay facilities are installed, such facilities shall be in excess of the required minimum facilities. Required facilities shall be free of charge.

Related Code Sections


403.3 Fixtures, Faucets and Fixture Fittings, Required Employee and Public Toilet Facilities
covered and open mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space ...
NYC Plumbing Code 2022 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Employee and Public Toilet Facilities
403.3 Fixtures, Faucets and Fixture Fittings, Required Employee and Public Toilet Facilities
covered mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required ...
NYC Plumbing Code 2014 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Employee and Public Toilet Facilities
403.3.1 Fixtures, Faucets and Fixture Fittings, Access
The route to the public toilet facilities required by Section 403.3 shall not pass through kitchens, storage rooms or closets. Access to the required ...
NYC Plumbing Code 2022 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Employee and Public Toilet Facilities > 403.3.1 Access
403.3.4 Fixtures, Faucets and Fixture Fittings, Pay Facilities
Where pay facilities are installed, such facilities shall be in excess of the required minimum facilities. Required facilities shall be free ...
NYC Plumbing Code 2014 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Employee and Public Toilet Facilities > 403.3.4 Pay Facilities
403.3.5 Fixtures, Faucets and Fixture Fittings, Pay Facilities
Where pay facilities are installed, such facilities shall be in excess of the required minimum facilities. Required facilities shall be free ...
NYC Plumbing Code 2022 > 4 Fixtures, Faucets and Fixture Fittings > 403 Minimum Plumbing Facilities > 403.3 Required Employee and Public Toilet Facilities > 403.3.5 Pay Facilities
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING