8.6.3.4 Replacement of Governor or Safety Rope
Go To Full Code Chapter
8.6.3.4.1
Governor ropes shall be the same size, material, and construction as the rope specified by the governor manufacturer, except that a rope the same size but different material or construction shall be permitted to be installed in conformance with 8.7.2.19.
8.6.3.4.2
The replaced governor ropes shall comply with 2.18.5.
8.6.3.4.3
After a governor rope is replaced, the governor pull-through force shall be checked as specified in 8.6.4.20.2(b).
8.6.3.4.4
A test tag indicating the date when the pull-through test was performed shall be attached.
8.6.3.4.6
A new rope data tag conforming to 2.18.5.3 shall be installed at each rope replacement, and the date of the rope replacement shall be recorded in the maintenance records [8.6.1.4.1(b)(2)].