• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section XI Repeal

2018 Arkansas Plumbing Code > F Rules and Regulations Pertaining to Plumbing and/or Natural Gas Inspector Certification > XI Repeal
JUMP TO FULL CODE CHAPTER
All Regulations and parts of Regulations in conflict herewith are hereby repealed.

Related Code Sections


107.1.10 Scope and Administration, Repeal
All regulations and parts of regulations in conflict herewith are hereby repealed ...
2018 Arkansas Fuel Gas Code > 1 Scope and Administration > 107 Inspections and Testing > 107.1 General > 107.1.10 Repeal
Section 108 Administration, Repealer
All regulations and parts of regulations in conflict herewith are hereby repealed ...
Arkansas Mechanical Code 2010 > 1 Administration > 108 Repealer
Section XI Rules and Regulations Pertaining to Plumbing and/or Natural Gas Inspector Certification, Repeal
All Regulations and parts of Regulations in conflict herewith are hereby repealed ...
2018 Arkansas Plumbing Code > F Rules and Regulations Pertaining to Plumbing and/or Natural Gas Inspector Certification > XI Repeal
107.1 Scope and Administration, General
All regulations and parts of regulations in conflict herewith are hereby repealed ...
2018 Arkansas Fuel Gas Code > 1 Scope and Administration > 107 Inspections and Testing > 107.1 General
Section 107 Scope and Administration, Inspections and Testing
All regulations and parts of regulations in conflict herewith are hereby repealed ...
2018 Arkansas Fuel Gas Code > 1 Scope and Administration > 107 Inspections and Testing
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING