1910.184(e)(7) Repairing and Reconditioning Alloy Steel Chain Slings
JUMP TO FULL CODE CHAPTER
Worn or damaged alloy steel chain slings or attachments shall not be used until repaired. When welding or heat testing is performed, slings shall not be used unless repaired, reconditioned and proof tested by the sling manufacturer or an equivalent entity.
Mechanical coupling links or low carbon steel repair links shall not be used to repair broken lengths of chain.
Related Code Sections
1910.184(e)(7) Materials Handling and Storage, Repairing and Reconditioning Alloy Steel Chain Slings
Worn or damaged alloy steel chain slings or attachments shall not be used until repaired. When welding or heat testing is performed, slings shall ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(e) Alloy Steel Chain Slings > 1910.184(e)(7) Repairing and Reconditioning Alloy Steel Chain Slings
1910.184(e)(1) Materials Handling and Storage, Sling Identification
Alloy steel chain slings shall have permanently affixed durable identification stating size, grade, rated capacity, and reach ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(e) Alloy Steel Chain Slings > 1910.184(e)(1) Sling Identification
1910.184(e)(3) Materials Handling and Storage, Inspections
In addition to the inspection required by paragraph (d) of this section, a thorough periodic inspection of alloy steel chain slings in use shall ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(e) Alloy Steel Chain Slings > 1910.184(e)(3) Inspections
1910.184(e)(6) Materials Handling and Storage, Safe Operating Temperatures
Employers must permanently remove an alloy steel-chain slings from service if it is heated above 1000 degrees F. When exposed to service temperatures ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(e) Alloy Steel Chain Slings > 1910.184(e)(6) Safe Operating Temperatures
1910.184(h)(6) Materials Handling and Storage, Repairs
Only fiber rope slings made from new rope shall be used. Use of repaired or reconditioned fiber rope slings is prohibited ...
OSHA 1910 General Industry > N Materials Handling and Storage > 1910.184 Slings > 1910.184(h) Natural and Synthetic Fiber-Rope Slings > 1910.184(h)(6) Repairs