• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1704.24.1.3 Removal of Stories, Including Full Demolitions

NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.24 Standpipe System Special Inspection > 1704.24.1 Hydrostatic Pressure Testing > 1704.24.1.3 Removal of Stories, Including Full Demolitions
JUMP TO FULL CODE CHAPTER
Where stories are removed from a building served by an existing standpipe system, hydrostatic pressure tests of the entire system shall be performed prior to the commencement of work.

Related Code Sections


1704.22.1.3 Structural Tests and Special Inspections, Removal of Stories, Including Full Demolitions
Where stories are removed from a building served by an existing standpipe system, hydrostatic pressure tests of the entire system shall be performed ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.22 Standpipe System Special Inspection > 1704.22.1 Hydrostatic Pressure Testing > 1704.22.1.3 Removal of Stories, Including Full Demolitions
1704.24.1.3 Structural Tests and Special Inspections, Removal of Stories, Including Full Demolitions
Where stories are removed from a building served by an existing standpipe system, hydrostatic pressure tests of the entire system shall be performed ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.24 Standpipe System Special Inspection > 1704.24.1 Hydrostatic Pressure Testing > 1704.24.1.3 Removal of Stories, Including Full Demolitions
3306.5 Safeguards During Construction or Demolition, Submittal Documents for Demolition
-, or three- family dwelling. The full demolition of a fully detached building that is three stories or fewer and with a floor area of 5,000 square ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.5 Submittal Documents for Demolition
Section 3306 Safeguards During Construction or Demolition, Demolition
demolition equipment, other than handheld devices, is to be used in the full or partial demolition of a building or is to be used to remove debris or move ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3306 Demolition
3306.9.8 Safeguards During Construction or Demolition, Hazards to Be Removed
Hazards shall be removed in accordance with the following requirements: Before commencement of actual demolition, all glass in windows, doors ...
NYC Building Code 2008 > 33 Safeguards During Construction or Demolition > 3306 Demolition > 3306.9 Full Demolition and Partial Demolition Operations > 3306.9.8 Hazards to Be Removed
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE