• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R608.9.1.2 Removal of Stay-In-Place Form Material at Bolts

Residential Code 2015 of Utah > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.9 Requirements for Connections—General > R608.9.1 Connections Between Concrete Walls and Light-Framed Floor, Ceiling and Roof Systems > R608.9.1.2 Removal of Stay-In-Place Form Material at Bolts
JUMP TO FULL CODE CHAPTER
Holes in stay-in-place forms for installing bolts for attaching face-mounted wood ledger boards to the wall shall be not less than 4 inches (102 mm) in diameter for forms not greater than 11/2 inches (38 mm) in thickness, and increased 1 inch (25 mm) in diameter for each 1/2-inch (12.7 mm) increase in form thickness. Holes in stay-in-place forms for installing bolts for attaching face-mounted cold-formed steel tracks to the wall shall be not less than 4 inches (102 mm) square. The wood ledger board or steel track shall be in direct contact with the concrete at each bolt location.

Exception: A vapor retarder or other material less than or equal to 1/16 inch (1.6 mm) in thickness is permitted to be installed between the wood ledger or cold-formed track and the concrete.

Related Code Sections


R608.9.1.2 Wall Construction, Removal of Stay-In-Place Form Material at Bolts
Holes in stay-in-place forms for installing bolts for attaching face-mounted wood ledger boards to the wall shall be not less than 4 inches (102 mm ...
Residential Code 2015 of Utah > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.9 Requirements for Connections—General > R608.9.1 Connections Between Concrete Walls and Light-Framed Floor, Ceiling and Roof Systems > R608.9.1.2 Removal of Stay-In-Place Form Material at Bolts
R404.1.3.3.6.1 Foundations, Stay-In-Place Forms
Stay-in-place concrete forms shall comply with this section. Surface burning characteristics. The flame-spread index and smoke-developed index ...
Residential Code 2015 of Utah > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.6 Form Materials and Form Ties > R404.1.3.3.6.1 Stay-In-Place Forms
R608.5.1 Wall Construction, Concrete and Materials for Concrete
not apply where removable forms are used and workability and methods of consolidation permit concrete to be placed without honeycombs or voids ...
Residential Code 2015 of Utah > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.5 Materials > R608.5.1 Concrete and Materials for Concrete
R404.1.3.3.4 Foundations, Proportioning and Slump of Concrete
that are resistant to segregation, and are in accordance with the form manufacturer's recommendations. Slump of concrete placed in stay-in-place ...
Residential Code 2015 of Utah > 4 Foundations > R404 Foundation and Retaining Walls > R404.1 Concrete and Masonry Foundation Walls > R404.1.3 Concrete Foundation Walls > R404.1.3.3 Concrete, Materials for Concrete, and Forms > R404.1.3.3.4 Proportioning and Slump of Concrete
R608.4.1 Wall Construction, Surface Burning Characteristics
The flame spread index and smoke-developed index of forming material, other than foam plastic, left exposed on the interior shall comply with Section ...
Residential Code 2015 of Utah > 6 Wall Construction > R608 Exterior Concrete Wall Construction > R608.4 Stay-In-Place Forms > R608.4.1 Surface Burning Characteristics
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE