1133A.3 Removable Base Cabinets
JUMP TO FULL CODE CHAPTER
Sinks and work surfaces required by Section 1133A.4 (see Item 1 and Item 2) shall be provided with knee and toe space complying with Section 1133A.7. Base cabinets (including toeboard and shelving) directly under kitchen sinks and work surfaces shall be removable without the use of specialized tools or specialized knowledge in order to provide knee and toe space. The finish floor beneath kitchen sinks and work surfaces shall be extended to the wall.
Related Code Sections
1133A.3 Housing Accessibility, Removable Base Cabinets
Base cabinets (including toeboard and shelving) directly under kitchen sinks and work surfaces shall be removable without the use of specialized ...
California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1133A Kitchens > 1133A.3 Removable Base Cabinets
1133A.3 Housing Accessibility, Removable Base Cabinets
Base cabinets (including toeboard and shelving)
directly under kitchen sinks and work surfaces shall be
removable without the use of specialized ...
California Building Code 2019 (Vol 1 & 2) > 11A Housing Accessibility > 1133A Kitchens > 1133A.3 Removable Base Cabinets
11B-809.9.3 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Removable Base Cabinets
Exception: Removable base cabinets shall be permitted under sinks and work surfaces provided that all of the following conditions are met:
base cabinets ...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-809 Residential Dwelling Units > 11B-809.9 Kitchens > 11B-809.9.3 Removable Base Cabinets
11B-233.3.1.2.6.5 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Additional Requirements
clearances complying with Section 11B-809.10.
Removable base cabinets complying with Section 11B-809.9.3.
...
California Building Code 2019 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-233 Public Housing Facilities > 11B-233.3 Public Housing Facilities > 11B-233.3.1 Minimum Number: New Construction > 11B-233.3.1.2 Residential Dwelling Units With Adaptable Features > 11B-233.3.1.2.6 Public Housing Facility Site Impracticality > 11B-233.3.1.2.6.5 Additional Requirements
1133A.7 Housing Accessibility, Knee and Toe Space
and unobstructed,
or removable base cabinets in compliance
with Section 1133A.3 shall be provided.
The knee and toe space shall be 30 inches (762 mm ...
California Building Code 2019 (Vol 1 & 2) > 11A Housing Accessibility > 1133A Kitchens > 1133A.7 Knee and Toe Space