408.4.1 Remote Release
Go To Full Code Chapter
Remote release of locks on doors in a means of egress shall be provided with reliable means of operation, remote from the resident living areas, to release locks on all required doors. In Occupancy Condition 3 or 4, the arrangement, accessibility and security of the release mechanisms required for egress shall be such that with the minimum available staff at any time, the lock mechanisms are capable of being released within 2 minutes.
Exception: Provisions for remote locking and unlocking of occupied rooms in Occupancy Condition 4 are not required provided that not more than 10 locks are necessary to be unlocked in order to move occupants from one smoke compartment to a refuge area within 3 minutes. The opening of necessary locks shall be accomplished with not more than two separate keys.
Related Code Sections
408.4.1 Special Detailed Requirements Based on Occupancy and Use, Remote Release
Remote release of locks on doors in a means of egress shall be provided with reliable means of operation, remote from the resident living areas ...
408.4.1 Special Detailed Requirements Based on Occupancy and Use, Remote Release
Remote release of locks on doors in a means of egress shall be provided with reliable means of operation, remote from the resident living areas ...
26.21.2.5.2 Special Occupancy Requirements, Manual Release Valve
[214:5.2.6.2] Remote manual release valves, where ...
26.21.2.5.2.1 Special Occupancy Requirements,
Remote manual release valves, where required, shall be conspicuously located and accessible during a fire emergency. [214:5.2.6.2.1] ...
26.21.2.5.2.2 Special Occupancy Requirements,
Where remote manual release valves are not required, an inspector's test valve shall be provided for each pilot-head-operated system. [214:5.2.6.2.2] ...