9.3.3 Reinforcement Strain Limit in Nonprestressed Beams
Go To Full Code Chapter
9.3.3.1
Nonprestressed beams with Pu < 0.10fc'Ag shall be tension controlled in accordance with Table 21.2.2.
Related Code Sections
9.3.3 Beams, Reinforcement Strain Limit in Nonprestressed Beams
Nonprestressed beams with Pu < 0.10fc'Ag shall be tension controlled in accordance with Table 21.2.2 ...
9.3.3 Beams, Reinforcement Strain Limit in Nonprestressed Beams
For nonprestressed beams with Pu < 0.10f'cAg, εt shall be at least 0.004 ...
9.7.2 Beams, Reinforcement Spacing
For nonprestressed and Class C prestressed beams, spacing of bonded longitudinal reinforcement closest to the tension face shall not exceed s given ...
9.7.2 Beams, Reinforcement Spacing
For nonprestressed and Class C prestressed beams, spacing of bonded longitudinal reinforcement closest to the tension face shall not exceed s given ...
25.6.1 Reinforcement Details, Nonprestressed Reinforcement
Groups of parallel reinforcing bars bundled in contact to act as a unit shall be limited to four in any one bundle ...