• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1240.2 Refuse Rooms

Los Angeles Building Code > 12 Interior Environment > 1240 [AGR] Meat and Poultry Processing Plants > 1240.2 Refuse Rooms
JUMP TO FULL CODE CHAPTER

A separate refuse room shall be required in official establishments where accumulations of refuse occur. Refuse rooms shall be entirely separate from other rooms in the establishment, and shall provide for the following:

  1. Tight fitting doors.
  2. Ventilation.
  3. Drainage.
  4. Cleanup facilities.
  5. Floors and walls to a height of 6 feet (1829 mm) above the floor shall be impervious to moisture.
  6. Wall above 6 feet (1829 mm), and ceilings shall be moisture resistant.

Related Code Sections


1240.2 Interior Environment, Refuse Rooms
A separate refuse room shall be required in official establishments where accumulations of refuse occur. Refuse rooms shall be entirely separate from ...
Los Angeles Building Code > 12 Interior Environment > 1240 [AGR] Meat and Poultry Processing Plants > 1240.2 Refuse Rooms
601.5.3 Water Supply and Distribution,
The refuse rooms shall be provided with facilities for washing refuse cans and other equipment in the rooms ...
Los Angeles Plumbing Code > 6 Water Supply and Distribution > 601.0 General > 601.5 [AGR] Meat and Poultry Processing Plants > 601.5.3
713.13.3 Fire and Smoke Protection Features, Chute Access Rooms
Access openings for waste or linen chutes shall be located in rooms or compartments enclosed by not less than 1-hour fire barriers constructed ...
Los Angeles Building Code > 7 Fire and Smoke Protection Features > 713 Shaft Enclosures > 713.13 Waste and Linen Chutes and Incinerator Rooms > 713.13.3 Chute Access Rooms
105.2.1 Scope and Administration, Refusal to Issue Permit
, the fire code official shall not issue a permit, but shall return the application to the applicant with the refusal to issue such permit. Such refusal ...
2017 LA City Fire Code > 1 Scope and Administration > 105 Permits > 105.2 Application > 105.2.1 Refusal to Issue Permit
Section 6503 Pyroxylin (Cellulose Nitrate) Plastics, General Requirements
kind and accumulation of paper, refuse and other combustible material ...
2017 LA City Fire Code > 65 Pyroxylin (Cellulose Nitrate) Plastics > 6503 General Requirements
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE