§27-836 Refuse Collection Rooms
JUMP TO FULL CODE CHAPTER
A refuse collection room shall be provided for refuse reduction systems which utilize methods other than burning. Such rooms shall comply with the requirements of section 27-837 of this article.
- Existing refuse rooms and incinerator rooms which have been approved for such use, may be retained as approved.
- Existing incinerator combustion chambers may be used in whole or in part as refuse collection rooms provided the grates are removed and provided they comply with the provisions of section 27-837 of this article.
- Floors of refuse collection rooms shall be constructed of concrete and shall be sloped to a floor drain within the room, connected to the house drain. A hose connection shall be provided within the room.
- A hopper and cut-off door shall be provided at the bottom of the refuse chute. Where compacting equipment is used, it shall be located entirely within the enclosure of the refuse collection room except that motors, pumps and controls may be installed in adjacent rooms.
- Compacting equipment shall meet the criteria of the department of environmental protection and be approved. Where such equipment is installed so that the refuse flows directly into it, the compacting equipment may be used in place of the hopper and cut-off door. Compacting equipment shall be arranged to operate automatically when the level of refuse is not more than three feet below the lowest hopper door.
Related Code Sections
§27-836 Heating and Combustion Equipment, Refuse Collection Rooms
A refuse collection room shall be provided for refuse reduction systems which utilize methods other than burning. Such rooms shall comply ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 18 Refuse Disposal Systems > §27-836 Refuse Collection Rooms
Appendix A Selected Rules of the Department of Buildings [PDF] (page 71)
hereafter in new construction, refuse chutes shall be required for conveyance of garbage and rubbish to refuse collection rooms, except that refuse chutes ...
Appendix A Selected Rules of the Department of Buildings [PDF] (page 73)
Rules and Regulations (f)Collection room floors. The floor within the room for the collection of refuse shall be constructed of concrete and shall ...
Section 1213 Interior Environment, Refuse and Recyclable Storage
2 ) per dwelling unit, or a minimum of 350 square feet (32.516 m 2 ), whichever is less, for the storage of collected refuse and recyclables ...
Section 1213 Interior Environment, Refuse and Recyclable Storage
2 ) per dwelling unit, or a minimum of 350 square feet (32.516 m 2 ), whichever is less, for the storage of collected refuse and recyclables ...