• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

903.2.11.12 Refuse Collection and Disposal Areas

NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.12 Refuse Collection and Disposal Areas
JUMP TO FULL CODE CHAPTER
An automatic sprinkler system shall be installed throughout all areas used for the storage and sorting of refuse and recyclables.

Related Code Sections


903.2.10.5 Fire Protection Systems, Refuse Collection and Disposal Areas
An automatic sprinkler system shall be installed throughout all areas used for the storage and sorting of refuse and recyclables ...
NYC Building Code 2008 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.10 All Occupancies > 903.2.10.5 Refuse Collection and Disposal Areas
903.2.11.12 Fire Protection Systems, Refuse Collection and Disposal Areas
An automatic sprinkler system shall be installed throughout all areas used for the storage and sorting of refuse and recyclables ...
NYC Building Code 2014 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.2 Where Required > 903.2.11 Specific Building Areas and Hazards > 903.2.11.12 Refuse Collection and Disposal Areas
§27-836 Heating and Combustion Equipment, Refuse Collection Rooms
A refuse collection room shall be provided for refuse reduction systems which utilize methods other than burning. Such rooms shall comply ...
NYC 1968 Code (Vol I) > 14 Heating and Combustion Equipment > 18 Refuse Disposal Systems > §27-836 Refuse Collection Rooms
§27-954 Fire Alarm, Detection and Extinguishing Equipment, Required Sprinklers
and sorting areas. Workshops exceeding one hundred square feet except in one- and two-family dwellings. Refuse collection and disposal areas. Drying ...
NYC 1968 Code (Vol I) > 17 Fire Alarm, Detection and Extinguishing Equipment > 4 Automatic Sprinkler Requirements > §27-954 Required Sprinklers
3303.15.3 Safeguards During Construction or Demolition, Disposal
Collected concrete washout water shall be transported off site for treatment and disposal or contained on site until completely evaporated. Any ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3303 Safeguards and Maintenance of Site > 3303.15 Concrete Washout Water > 3303.15.3 Disposal
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE