1213.3 Refuse Chute

NYC Building Code 2014 > 12 Interior Environment > 1213 Refuse and Recyclable Storage > 1213.3 Refuse Chute
JUMP TO FULL CODE CHAPTER
buildings bulletin
Linked Resources Available

This section has been clarified by a buildings bulletin issued by the Department of Buildings.

Learn more in the Linked Resources panel on the right.
A multiple dwelling that is five or more stories in height and that contains more than 9 or more dwelling units shall be provided with a refuse chute, refuse chute access rooms, and refuse chute termination room constructed in accordance with Section 707.13. A minimum of 5 square feet (0.470 m2) of floor area within each refuse chute access room shall be provided for the temporary holding of recyclables. Such floor area shall be clearly identified on the construction documents. In I-1 and R-1 occupancies, access to the chute access room shall be permitted to be restricted to employees provided that separate refuse storage rooms are located on each story for general occupant use.

Exceptions:

1. In buildings without an elevator, floor area within refuse chute access rooms for the temporary holding of recyclables is not required.

2. In buildings equipped with separate chutes designated for refuse, for paper and cardboard, and for metal, glass and plastic, and in buildings equipped with a chute system that provides for source separation of recyclable materials without cross contamination, floor area within refuse chute access rooms for the temporary holding of recyclables is not required. Chutes for designated recyclable materials shall be constructed in accordance with Section 707.13 of this code.

3. The refuse chute and the occupant use storage rooms shall not be required in transient hotels meeting the following requirements:

3.1. the refuse is removed from rooms by a daily cleaning service, with the staff using a service elevator that is not accessed by hotel guests;

3.2. the building is of Group I or Group II construction; or

3.3. a compactor and refuse storage room is provided in accordance with Section 1213.2.

1213.3.1 Refuse Chute Access Room Floor and Wall Base Finish Materials

Refuse chute access rooms shall have a smooth, hard and nonabsorbent surface. The intersection of such floors with walls shall have a smooth, hard and nonabsorbent vertical base that extends upward onto the walls at least 4 inches (101.6 mm).
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


1207.3.1 Interior Environment, Refuse Chutes
Metal refuse chutes, metal chute supports, and/or metal chute bracing shall be free of direct contact with the shaft enclosure and the openings ...
NYC Building Code 2014 > 12 Interior Environment > 1207 Sound Transmission > 1207.3 Structure-Borne Sound > 1207.3.1 Refuse Chutes
1207.3.1 Interior Environment, Refuse Chutes
Metal refuse chutes, metal chute supports, and/or metal chute bracing shall be free of direct contact with the shaft enclosure and the openings ...
NYC Building Code 2008 > 12 Interior Environment > 1207 Sound Transmission > 1207.3 Structure-Borne Sound > 1207.3.1 Refuse Chutes
1213.3 Interior Environment, Refuse Chute
A multiple dwelling that is five or more stories in height and that contains more than 9 or more dwelling units shall be provided with a refuse chute ...
NYC Building Code 2014 > 12 Interior Environment > 1213 Refuse and Recyclable Storage > 1213.3 Refuse Chute
Chapter 24 Refuse Chutes and Refuse Rooms
Title 1 ‒ Department of Buildings > 24 Refuse Chutes and Refuse Rooms
§24-01 Refuse Chutes and Refuse Rooms, Construction and Maintenance of Refuse Chutes and Refuse Rooms
   (a)    Refuse chute enclosures. Refuse chutes used for conveyance of garbage and rubbish from upper floors ...
Title 1 ‒ Department of Buildings > 24 Refuse Chutes and Refuse Rooms > §24-01 Construction and Maintenance of Refuse Chutes and Refuse Rooms
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Contact Careers Terms Privacy
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US