708.13.3 Refuse and Laundry Chute Access Rooms
JUMP TO FULL CODE CHAPTER
Access openings for refuse and laundry chutes shall be located in dedicated rooms or compartments enclosed by not less than 2-hour fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 712, or both. Openings into the access rooms shall be protected by opening protectives having a fire protection rating of not less than 11/2 hour. Doors shall be self closing except that where the storage of refuse, including recyclables, or laundry is not permitted in such access rooms doors may be automatic closing upon the detection of smoke in accordance with Section 715.4.8.3.
Exception: Access openings for refuse or laundry chutes located within a dwelling unit need not be located within a separate room or compartment.
Related Code Sections
707.13.3 Fire-Resistance-Rated Construction, Refuse and Laundry Chute Access Rooms
Access openings for refuse and laundry chutes shall be located in dedicated rooms or compartments completely enclosed by construction that has a fire ...
NYC Building Code 2008 > 7 Fire-Resistance-Rated Construction > 707 Shaft Enclosures > 707.13 Refuse and Laundry Chutes > 707.13.3 Refuse and Laundry Chute Access Rooms
708.13.3 Fire and Smoke Protection Features, Refuse and Laundry Chute Access Rooms
Access openings for refuse and laundry chutes shall be located in dedicated rooms or compartments enclosed by not less than 2-hour fire barriers ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 708 Shaft Enclosures > 708.13 Refuse and Laundry Chutes > 708.13.3 Refuse and Laundry Chute Access Rooms
715.4.8.3 Fire and Smoke Protection Features, Smoke-Activated Doors
in shaft enclosures in accordance with Section 708.7. Doors installed in refuse and laundry chutes and access and termination rooms in accordance ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 715 Opening Protectives > 715.4 Fire Door and Shutter Assemblies > 715.4.8 Door Closing > 715.4.8.3 Smoke-Activated Doors
1213.3 Interior Environment, Refuse Chute
chute access rooms, and refuse chute termination room constructed in accordance with Section 707.13. A minimum of 5 square feet (0.470 m 2 ) of floor ...
NYC Building Code 2014 > 12 Interior Environment > 1213 Refuse and Recyclable Storage > 1213.3 Refuse Chute
715.4.8 Fire and Smoke Protection Features, Door Closing
installed in shaft enclosures in accordance with Section 708.7. Doors installed in refuse and laundry chutes and access and termination rooms ...
NYC Building Code 2014 > 7 Fire and Smoke Protection Features > 715 Opening Protectives > 715.4 Fire Door and Shutter Assemblies > 715.4.8 Door Closing