• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1224.29.2.10.3 Refrigerated Storage and Warming Facilities for Infant Formula

California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.10 Infant Formula Facilities > 1224.29.2.10.3 Refrigerated Storage and Warming Facilities for Infant Formula
JUMP TO FULL CODE CHAPTER
Shall be accessible for use by NICU personnel at all times.

Related Code Sections


1224.29.2.10.3 Interior Environment, Refrigerated Storage and Warming Facilities for Infant Formula
Shall be accessible for use by NICU personnel at all times ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.10 Infant Formula Facilities > 1224.29.2.10.3 Refrigerated Storage and Warming Facilities for Infant Formula
1224.29.2.10.3 Interior Environment, Refrigerated Storage and Warming Facilities for Infant Formula
Shall be accessible for use by NICU personnel at all times ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.10 Infant Formula Facilities > 1224.29.2.10.3 Refrigerated Storage and Warming Facilities for Infant Formula
1224.29.2.10 Interior Environment, Infant Formula Facilities
Nourishment area required under Section 1224.29.1.14.4 not required. Newborn intensive care units shall include infant formula facilities complying ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.10 Infant Formula Facilities
1224.30.3.2 Interior Environment, Infant Formula
Space for preparation and storage of infant formula shall be provided immediately accessible to the unit ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.30 Pediatric and Adolescent Unit > 1224.30.3 Service Areas > 1224.30.3.2 Infant Formula
1224.29.2.10.4 Interior Environment, Commercial Infant Formula
Where only commercially prepared infant formula is used, omission of the formula preparation room may be permitted. Storage and handling may occur ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.29 Intensive Care Units > 1224.29.2 Newborn Intensive Care Units (NICU) > 1224.29.2.10 Infant Formula Facilities > 1224.29.2.10.4 Commercial Infant Formula
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING