P2902.3.5 Reduced Pressure Principle Backflow Preven- Ters
JUMP TO FULL CODE CHAPTER
Reduced pressure principle backflow preventers shall conform to ASSE 1013, AWWA C511, CSA B64.4 or CSA B64.4.1. Reduced pressure detector assembly backflow preventers shall conform to ASSE 1047. These devices shall be permitted to be installed where subject to continuous pressure conditions. The relief opening shall discharge by air gap and shall be prevented from being submerged.
Related Code Sections
P2902.3.5 Water Supply and Distribution, Reduced Pressure Principle Backflow Preven- Ters
Reduced pressure principle backflow preventers shall conform to ASSE 1013, AWWA C511, CSA B64.4 or CSA B64.4.1. Reduced pressure detector assembly ...
2010 Residential Code of NY > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.3 Backflow Protection > P2902.3.5 Reduced Pressure Principle Backflow Preven- Ters
P2902.5.4 Water Supply and Distribution, Connections to Automatic Fire Sprinkler Systems
, a double-check fire protection backflow prevention assembly, a reduced pressure principle backflow prevention assembly or a reduced pressure principle ...
2020 Residential Code of New York State > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.5 Protection of Potable Water Connections > P2902.5.4 Connections to Automatic Fire Sprinkler Systems
P2902.5.4 Water Supply and Distribution, Connections to Automatic Fire Sprinkler Systems
, a double check fire protection backflow prevention assembly, a reduced pressure principle backflow prevention assembly or a reduced pressure principle ...
Residential Code 2015 of New York State > 29 Water Supply and Distribution > P2902 Protection of Potable Water Supply > P2902.5 Protection of Potable Water Connections > P2902.5.4 Connections to Automatic Fire Sprinkler Systems
608.16.4.1 Water Supply and Distribution, Additives or Nonpotable Source
supply, the potable water supply shall be protected against backflow by a reduced pressure principle backflow prevention assembly or a reduced pressure ...
Plumbing Code 2015 of New York State > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.16 Connections to the Potable Water System > 608.16.4 Connections to Automatic Fire Sprinkler Systems and Standpipe Systems > 608.16.4.1 Additives or Nonpotable Source
608.17.4.1 Water Supply and Distribution, Additives or Nonpotable Source
supply, the potable water supply shall be protected against backflow by a reduced pressure principle backflow prevention assembly or a reduced pressure ...
2020 Plumbing Code of NYS > 6 Water Supply and Distribution > 608 Protection of Potable Water Supply > 608.17 Connections to the Potable Water System > 608.17.4 Connections to Automatic Fire Sprinkler Systems and Standpipe Systems > 608.17.4.1 Additives or Nonpotable Source