R602.10.11.3 Redesignation of Cripple Walls
JUMP TO FULL CODE CHAPTER
Where all cripple wall segments along a braced wall line do not exceed 48 inches (1219 mm) in height, the cripple walls shall be permitted to be redesignated as a first-story wall for purposes of determining wall bracing requirements. Where any cripple wall segment in a braced wall line exceeds 48 inches (1219 mm) in height, the entire cripple wall shall be counted as an additional story. If the cripple walls are redesignated, the stories above the redesignated story shall be counted as the second and third stories, respectively.
Related Code Sections
R602.10.10.3 Wall Construction, Redesignation of Cripple Walls
to be redesignated as a first- story wall for purposes of determining wall bracing requirements. Where any cripple wall segment in a braced wall line ...
2020 Minnesota Residential Code > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.10 Cripple Wall Bracing > R602.10.10.3 Redesignation of Cripple Walls
R602.10.11.3 Wall Construction, Redesignation of Cripple Walls
to be redesignated as a first- story wall for purposes of determining wall bracing requirements. Where any cripple wall segment in a braced wall line ...
Minnesota Residential Code 2015 > 6 Wall Construction > R602 Wood Wall Framing > R602.10 Wall Bracing > R602.10.11 Cripple Wall Bracing > R602.10.11.3 Redesignation of Cripple Walls
2308.5.6 Wood, Cripple Walls
Foundation cripple walls shall be framed of studs that are not less than the size of the studding above and not less than 14 inches (356 mm ...
2020 Minnesota Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.5 Wall Construction > 2308.5.6 Cripple Walls
2308.9.4 Wood, Cripple Walls
Foundation cripple walls shall be framed of studs not less in size than the studding above with a minimum length of 14 inches (356 mm), or shall ...
Minnesota Building Code 2015 > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.9 Wall Framing > 2308.9.4 Cripple Walls
2308.6.6 Wood, Cripple Wall Bracing
Cripple walls shall be braced in accordance with Section 2308.6.6.1 or 2308.6.6.2 ...
2020 Minnesota Building Code > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.6 Wall Bracing > 2308.6.6 Cripple Wall Bracing