E 506.0 Recreational Vehicle Park Water Supply Stations
Go To Full Code Chapter
E 506.1 Potable Watering Stations
A potable watering station, where provided for filling recreational vehicle potable water tanks, shall be located not less than 50 feet (15 240 mm) from a sanitary disposal station. Where such is provided, adjacent to the potable water outlet there shall be a posted sign of durable material not less than 2 feet by 2 feet (610 mm by 610 mm) in size. Inscribed thereon in clear, legible letters on a contrasting background shall be:
"POTABLE WATER. NOT TO BE USED FOR FLUSHING WASTE TANKS."
The potable water shall be protected from backflow using a listed vacuum breaker located downstream from the last shutoff valve.
Related Code Sections
E 506.0 Manufactured/Mobile Home Parks and Recreational Vehicle Parks, Recreational Vehicle Park Water Supply Stations
A potable watering station, where provided for filling recreational vehicle potable water tanks, shall be located not less than 50 feet (15 240 mm ...
E 505.4 Manufactured/Mobile Home Parks and Recreational Vehicle Parks, Flushing Device
Where the recreational vehicle park is provided with a piped water supply system, means for flushing the recreational vehicle holding tank ...
E 502.4 Manufactured/Mobile Home Parks and Recreational Vehicle Parks, Supply
The water supply system shall be designed and constructed in accordance with the following:
A minimum of 25 gallons (95 L) per day per site ...
E 501.4 Manufactured/Mobile Home Parks and Recreational Vehicle Parks, Lavatories
Where water-supplied water closets are provided, an equal number of lavatories shall be provided for up to six water closets. One additional lavatory ...
Article 551 Special Occupancies, Recreational Vehicles and Recreational Vehicle Parks
the park service equipment to the recreational vehicle site supply equipment.
Recreational Vehicle Site Supply Equipment. This definition shall apply ...