• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1910.423(c) Recompression Capability

OSHA 1910 General Industry > T Commercial Diving Operations > 1910.423 Post-Dive Procedures > 1910.423(c) Recompression Capability
JUMP TO FULL CODE CHAPTER

1910.423(c)(1)

A decompression chamber capable of recompressing the diver at the surface to a minimum of 165 fsw (6 ATA) shall be available at the dive location for:

1910.423(c)(1)(i)

Surface-supplied air diving to depths deeper than 100 fsw and shallower than 220 fsw;

1910.423(c)(1)(iii)

Diving outside the no-decompression limits shallower than 300 fsw.

1910.423(c)(1)(ii)

Mixed gas diving shallower than 300 fsw; or

1910.423(c)(2)

A decompression chamber capable of recompressing the diver at the surface to the maximum depth of the dive shall be available at the dive location for dives deeper than 300 fsw.

1910.423(c)(3) The Decompression Chamber Shall Be:

1910.423(c)(3)(i) Dual-Lock

1910.423(c)(3)(iii) Located Within 5 Minutes of the Dive Location

1910.423(c)(3)(ii) Multiplace; And

1910.423(c)(4) The Decompression Chamber Shall Be Equipped With:

1910.423(c)(4)(i)

A pressure gauge for each pressurized compartment designed for human occupancy;

1910.423(c)(4)(iii)

A two-way voice communication system between occupants and a dive team member at the dive location;

1910.423(c)(4)(iv) A Viewport; And

1910.423(c)(4)(v) Illumination Capability to Light the Interior

1910.423(c)(4)(ii)

A built-in-breathing-system with a minimum of one mask per occupant;

1910.423(c)(5)

Treatment tables, treatment gas appropriate to the diving mode, and sufficient gas to conduct treatment shall be available at the dive location.

1910.423(c)(6)

A dive team member shall be available at the dive location during and for at least one hour after the dive to operate the decompression chamber (when required or provided).

Related Code Sections


1910.423(c) Commercial Diving Operations, Recompression Capability
A decompression chamber capable of recompressing the diver at the surface to a minimum of 165 fsw (6 ATA) shall be available at the dive location ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.423 Post-Dive Procedures > 1910.423(c) Recompression Capability
1910.423(c)(3) Commercial Diving Operations, The Decompression Chamber Shall Be:
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.423 Post-Dive Procedures > 1910.423(c) Recompression Capability > 1910.423(c)(3) The Decompression Chamber Shall Be:
1910.423(c)(4) Commercial Diving Operations, The Decompression Chamber Shall Be Equipped With:
A pressure gauge for each pressurized compartment designed for human occupancy ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.423 Post-Dive Procedures > 1910.423(c) Recompression Capability > 1910.423(c)(4) The Decompression Chamber Shall Be Equipped With:
1910.423(c)(5) Commercial Diving Operations,
Treatment tables, treatment gas appropriate to the diving mode, and sufficient gas to conduct treatment shall be available at the dive location ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.423 Post-Dive Procedures > 1910.423(c) Recompression Capability > 1910.423(c)(5)
1910.423(c)(6) Commercial Diving Operations,
A dive team member shall be available at the dive location during and for at least one hour after the dive to operate the decompression chamber (when ...
OSHA 1910 General Industry > T Commercial Diving Operations > 1910.423 Post-Dive Procedures > 1910.423(c) Recompression Capability > 1910.423(c)(6)
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING