• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3126B Recirculation Pump Capacity

Los Angeles Building Code > 31B [DPH] Public Pools > 3126B Recirculation Pump Capacity
JUMP TO FULL CODE CHAPTER

3126B.1

Pool recirculation pumps shall have the following total dynamic head capacities:

  1. Pressure diatomaceous earth filters. At least 60 feet (18,288 mm); and
  2. Vacuum diatomaceous earth filters. Twenty inches (508 mm) vacuum on the suction side and 40 feet (12,192 mm) total dynamic head;and
  3. Rapid sand filters. At least 45 feet (13,716 mm); and
  4. High rate sand filters. At least 60 feet (18,288 mm); and
  5. Cartridge filters. At least 60 feet (18,288 mm).

3126B.2

Pumps with other total dynamic head capacities shall be permitted provided the turnover times are maintained as required in Section 3124B.

Related Code Sections


Section 3126B [DPH] Public Pools, Recirculation Pump Capacity
Pool recirculation pumps shall have the following total dynamic head capacities: Pressure diatomaceous earth filters. At least 60 feet (18,288 mm ...
Los Angeles Building Code > 31B [DPH] Public Pools > 3126B Recirculation Pump Capacity
3109.4.4.8 Special Construction, Construction Requirements for Building a Pool or Spa
to conduct water to the recirculation pump. The circulation system shall have the capacity to provide a complete turnover of pool water, as specified ...
Los Angeles Building Code > 31 Special Construction > 3109 Swimming Pool Enclosures and Safety Devices > 3109.4 Residential Swimming Pools > 3109.4.4 Private Swimming Pools (Statewide) > 3109.4.4.8 Construction Requirements for Building a Pool or Spa
AV100.8 Swimming Pool Safety Act, Construction Requirements for Building a Pool or Spa
to conduct water to the recirculation pump. The circulation system shall have the capacity to provide a complete turnover of pool water, as specified ...
Los Angeles Residential Code > V Swimming Pool Safety Act > AV100 Private Swimming Pools (Statewide) > AV100.8 Construction Requirements for Building a Pool or Spa
2404.7.2 Flammable Finishes, Recirculation
Air exhausted from spraying operations shall not be recirculated. Exceptions: Air exhausted from spraying operations is allowed ...
2017 LA City Fire Code > 24 Flammable Finishes > 2404 Spray Finishing > 2404.7 Ventilation > 2404.7.2 Recirculation
516.2.2 Exhaust Systems, Recirculation
Recirculating systems shall be listed with a testing laboratory in accordance with UL 710B or equivalent. [NFPA 96:13.2.4] ...
Los Angeles Mechanical Code > 5 Exhaust Systems > 516.0 Recirculating Systems > 516.2 Design Restrictions > 516.2.2 Recirculation
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE