M1505.2 Recirculation of Air
JUMP TO FULL CODE CHAPTER
Exhaust air from bathrooms and toilet rooms shall not be recirculated within a residence or circulated to another dwelling unit and shall be exhausted directly to the outdoors. Exhaust air from bathrooms, toilet rooms and kitchens shall not discharge into an attic, crawl space or other areas inside the building. This section shall not prohibit the installation of ductless range hoods in accordance with the exception to Section M1503.3.
Related Code Sections
403.2.1 Ventilation, Recirculation of Air
The outdoor air required by Section 403.3 shall not be recirculated. Air in excess of that required by Section 403.3 shall not be prohibited from ...
Mechanical Code 2018 of Kansas > 4 Ventilation > 403 Mechanical Ventilation > 403.2 Outdoor Air Required > 403.2.1 Recirculation of Air
M1505.2 Exhaust Systems, Recirculation of Air
Exhaust air from bathrooms and toilet rooms shall not be recirculated within a residence or circulated to another dwelling unit and shall ...
Residential Code 2018 of Kansas > 15 Exhaust Systems > M1505 Mechanical Ventilation > M1505.2 Recirculation of Air
514.4 Exhaust Systems, Recirculated Air
Air conveyed within energy recovery systems shall not be considered as recirculated air where the energy recovery ventilation system is constructed ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 514 Energy Recovery Ventilation Systems > 514.4 Recirculated Air
902.1.1 Alterations—Level 3, Recirculating Air or Exhaust Systems
Where a floor is served by a recirculating air or exhaust system with a capacity greater than 15,000 cubic feet per minute (701 m 3 /s), that system ...
Existing Building Code 2018 of Kansas > 9 Alterations—Level 3 > 902 Special Use and Occupancy > 902.1 High-Rise Buildings > 902.1.1 Recirculating Air or Exhaust Systems
502.7.3.2 Exhaust Systems, Recirculation
Air exhausted from spraying operations shall not be recirculated. Exceptions: Air exhausted from spraying operations shall be permitted ...
Mechanical Code 2018 of Kansas > 5 Exhaust Systems > 502 Required Systems > 502.7 Application of Flammable Finishes > 502.7.3 Flammable Vapor Areas > 502.7.3.2 Recirculation