• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E4003.5 Recessed Incandescent Luminaires

2015 Michigan Residential Code > 40 Devices and Luminaires > E4003 Luminaires > E4003.5 Recessed Incandescent Luminaires
JUMP TO FULL CODE CHAPTER
Recessed incandescent luminaires shall have thermal protection and shall be listed as thermally protected. [410.115(C)]

Exceptions:
  1. Thermal protection shall not be required in recessed luminaires listed for the purpose and installed in poured concrete. [410.115(C) Exception No.1]
  2. Thermal protection shall not be required in recessed luminaires having design, construction, and thermal performance characteristics equivalent to that of thermally protected luminaires, and such luminaires are identified as inherently protected. [410.115(C) Exception No. 2]

Related Code Sections


E4003.5 Devices and Luminaires, Recessed Incandescent Luminaires
Recessed incandescent luminaires shall have thermal protection and shall be listed as thermally protected. [410.115(C)] Exceptions ...
2015 Michigan Residential Code > 40 Devices and Luminaires > E4003 Luminaires > E4003.5 Recessed Incandescent Luminaires
E4004.8 Devices and Luminaires, Recessed Luminaire Clearance
A recessed luminaire that is not identified for contact with insulation shall have all recessed parts spaced at least 1 / 2 inch (12.7 mm) from ...
2015 Michigan Residential Code > 40 Devices and Luminaires > E4004 Luminaire Installation > E4004.8 Recessed Luminaire Clearance
E4001.12 Devices and Luminaires, Dimmer Switches
General-use dimmer switches shall be used only to control permanently installed incandescent luminaires (lighting fixtures) except where listed ...
2015 Michigan Residential Code > 40 Devices and Luminaires > E4001 Switches > E4001.12 Dimmer Switches
N1102.4.4 [RE] Energy Efficiency, (R402.4.4) Recessed Lighting (Mandatory)
Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces. All ...
2015 Michigan Residential Code > 11 [RE] Energy Efficiency > N1102 Building Thermal Envelope > N1102.4 (R402.4) Air Leakage > N1102.4.4 (R402.4.4) Recessed Lighting (Mandatory)
E4004.7 Devices and Luminaires, Combustible Low-Density Cellulose Fiberboard
of the fiberboard. Where such luminaires are partially or wholly recessed, the provisions of Sections E4004.8 and E4004.9 shall apply. [410.136(B)] ...
2015 Michigan Residential Code > 40 Devices and Luminaires > E4004 Luminaire Installation > E4004.7 Combustible Low-Density Cellulose Fiberboard
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE