E4207.4 Receptacle Locations
JUMP TO FULL CODE CHAPTER
Receptacles shall be located not less than 6 feet (1829 mm) from the inside walls of a storable pool, storable spa or storable hot tub. In determining these dimensions, the distance to be measured shall be the shortest path that the supply cord of an appliance connected to the receptacle would follow without passing through a floor, wall, ceiling, doorway with hinged or sliding door, window opening, or other effective permanent barrier. (680.34)
Related Code Sections
E4207.4 Swimming Pools, Receptacle Locations
Receptacles shall be located not less than 6 feet (1829 mm) from the inside walls of a storable pool, storable spa or storable hot tub. In ...
Residential Code 2015 of New York State > 42 Swimming Pools > E4207 Storable Swimming Pools, Storable Spas, and Storable Hot Tubs > E4207.4 Receptacle Locations
E4207.4 Swimming Pools, Receptacle Locations
Receptacles shall be located not less than 6 feet (1829 mm) from the inside walls of a storable pool, storable spa or storable hot tub. In ...
2020 Residential Code of New York State > 42 Swimming Pools > E4207 Storable Swimming Pools, Storable Spas, and Storable Hot Tubs > E4207.4 Receptacle Locations
E3801.4.5 Power and Lighting Distribution, Receptacle Outlet Location
Receptacle outlets shall be located not more than 20 inches (508 mm) above the countertop. Receptacle outlets shall not be installed in a face-up ...
2010 Residential Code of NY > 38 Power and Lighting Distribution > E3801 Receptacle Outlets > E3801.4 Countertop Receptacles > E3801.4.5 Receptacle Outlet Location
E3901.4.5 Power and Lighting Distribution, Receptacle Outlet Location
Receptacle outlets shall be located not more than 20 inches (508 mm) above the countertop. Receptacle outlet assemblies installed in countertops ...
Residential Code 2015 of New York State > 39 Power and Lighting Distribution > E3901 Receptacle Outlets > E3901.4 Countertop Receptacles > E3901.4.5 Receptacle Outlet Location
E3901.4.5 Power and Lighting Distribution, Receptacle Outlet Location
Receptacle outlets shall be located not more than 20 inches (508 mm) above the countertop or work surface. Receptacle outlet assemblies installed ...
2020 Residential Code of New York State > 39 Power and Lighting Distribution > E3901 Receptacle Outlets > E3901.4 Countertop and Work Surface Receptacles > E3901.4.5 Receptacle Outlet Location