• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

(B) Receptacle

National Electrical Code 2020 of Minnesota > 6 Special Equipment > 626 Electrified Truck Parking Spaces > 626.24 Electrified Truck Parking Space Supply Equipment Connection Means > (B) Receptacle
JUMP TO FULL CODE CHAPTER
All receptacles shall be listed and of the grounding type. Every truck parking space with electrical supply shall be equipped with 626.24(B)(1) and (B)(2).
  1. A maximum of three receptacles, each 2-pole, 3-wire grounding type and rated 20 amperes, 125 volts, and two of the three connected to two separate branch circuits.
    Informational Note: For the non-locking-type and grounding-type 20-ampere receptacle configuration, see ANSI/NEMA WD 6-2016, Wiring Devices — Dimensional Specifications, Figure 5-20.
  2. One single receptacle, 3-pole, 4-wire grounding type, single phase rated either 30 amperes 208Y/120 volts or 125/250 volts. The 125/250-volt receptacle shall be permitted to be used on a 208Y/120-volt, single-phase circuit.
    Informational Note: For various configurations of 30-ampere pin and sleeve receptacles, see ANSI/UL 1686-2012, Standard for Pin and Sleeve Configurations, Figure C2.9 or Part C3.
Exception: Where electrified truck parking space supply equipment provides the heating, air-conditioning, and comfort-cooling function without requiring a direct electrical connection at the truck, only two receptacles identified in 626.24(B)(1) shall be required.

Related Code Sections


(B) Wiring and Protection, Receptacles
A single receptacle installed on an individual branch circuit shall have an ampere rating not less than that of the branch circuit. Exception No. 1 ...
National Electrical Code 2020 of Minnesota > 2 Wiring and Protection > 210 Branch Circuits > 210.21 Outlet Devices > (B) Receptacles
(A) Wiring Methods and Materials, Receptacles
All receptacles, receptacle housings, and self-contained devices used with the FCC system shall be identified for this use and shall be connected ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 324 Flat Conductor Cable: Type FCC > 324.42 Devices > (A) Receptacles
(A) Wiring Methods and Materials, Receptacles
All receptacles, receptacle housings, and self-contained devices used with concealable nonmetallic extensions shall be identified for this use ...
National Electrical Code 2020 of Minnesota > 3 Wiring Methods and Materials > 382 Nonmetallic Extensions > 382.42 Devices > (A) Receptacles
406.1.1 Repairs, Receptacles
Replacement of electrical receptacles shall comply with the applicable requirements of Section 406.4(D) of NFPA 70 ...
2020 Minnesota Conservation Code for Existing Buildings > 4 Repairs > 406 Electrical > 406.1 Material > 406.1.1 Receptacles
(A) Equipment for General Use, Receptacles
Receptacles shall be listed and marked with the manufacturer's name or identification and voltage and ampere ratings. Receptacles shall ...
National Electrical Code 2020 of Minnesota > 4 Equipment for General Use > 406 Receptacles, Cord Connectors, and Attachment Plugs (Caps) > 406.3 Receptacle Rating and Type > (A) Receptacles
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING