• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

E4002.1 Rating and Type

2015 Michigan Residential Code > 40 Devices and Luminaires > E4002 Receptacles > E4002.1 Rating and Type
JUMP TO FULL CODE CHAPTER
Receptacles and cord connectors shall be rated at not less than 15 amperes, 125 volts, or 15 amperes, 250 volts, and shall not be a lampholder type. Receptacles shall be rated in accordance with this section. [406.3(B)]

E4002.1.1 Single Receptacle

A single receptacle installed on an individual branch circuit shall have an ampere rating not less than that of the branch circuit. [210.21(B)]

E4002.1.2 Two or More Receptacles

Where connected to a branch circuit supplying two or more receptacles or outlets, receptacles shall conform to the values listed in Table E4002.1.2. [210.21(B)(3)]

TABLE E4002.1.2 [Table 210.21 (B)(3)]
RECEPTACLE RATINGS FOR VARIOUS SIZE MULTI-OUTLET CIRCUITS
CIRCUIT RATING (amperes) RECEPTACLE RATING (amperes)
15 15
20 15 or 20
30 30
40 40 or 50
50 50

Related Code Sections


E4002.1 Devices and Luminaires, Rating and Type
Receptacles and cord connectors shall be rated at not less than 15 amperes, 125 volts, or 15 amperes, 250 volts, and shall not be a lampholder type ...
2015 Michigan Residential Code > 40 Devices and Luminaires > E4002 Receptacles > E4002.1 Rating and Type
403.2.1.1 Special Detailed Requirements Based on Use and Occupancy, Type of Construction
not greater than 420 feet (128000 mm) in building height, the fire-resistance rating of the building elements in Type IA construction shall ...
2015 Michigan Building Code > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.2 Construction > 403.2.1 Reduction in Fire-Resistance Rating > 403.2.1.1 Type of Construction
705.2.3 Fire and Smoke Protection Features, Combustible Projections
-hour fire-resistance-rated construction, Type IV construction, fire-retardant-treated wood or as required by Section 1406.3 ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 705 Exterior Walls > 705.2 Projections > 705.2.3 Combustible Projections
717.3.2.1 Fire and Smoke Protection Features, Fire Damper Ratings
Fire dampers shall have the minimum fire protection rating specified in Table 717.3.2.1 for the type of penetration. TABLE 717.3.2.1 FIRE ...
2015 Michigan Building Code > 7 Fire and Smoke Protection Features > 717 Ducts and Air Transfer Openings > 717.3 Damper Testing, Ratings and Actuation > 717.3.2 Damper Rating > 717.3.2.1 Fire Damper Ratings
607.3.2.1 Duct Systems, Fire Damper Ratings
Fire dampers shall have the minimum fire protection rating specified in Table 607.3.2.1 for the type of penetration. [BF] TABLE ...
2015 Michigan Mechanical Code > 6 Duct Systems > 607 Duct and Transfer Openings > 607.3 Damper Testing, Ratings and Actuation > 607.3.2 Damper Rating > 607.3.2.1 Fire Damper Ratings
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE