• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1926.1433(d)(1) Rated Capacity and Related Information

OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(1) Rated Capacity and Related Information
JUMP TO FULL CODE CHAPTER
The information available in the cab (see § 1926.1417(c)) regarding "rated capacity" and related information must include, at a minimum, the following information:

1926.1433(d)(1)(i)

A complete range of the manufacturer's equipment rated capacities, as follows:

1926.1433(d)(1)(i)(A)

At all manufacturer approved operating radii, boom angles, work areas, boom lengths and configurations, jib lengths and angles (or offset).

1926.1433(d)(1)(i)(B)

Alternate ratings for use and nonuse of option equipment which affects rated capacities, such as outriggers, stabilizers, and extra counterweights.

1926.1433(d)(1)(iii)

The work area figure and load chart must clearly indicate the areas where no load is to be handled.

1926.1433(d)(1)(iv)

Recommended reeving for the hoist lines must be shown.

1926.1433(d)(1)(ix)

Position of the gantry and requirements for intermediate boom suspension (where applicable).

1926.1433(d)(1)(v)

Recommended parts of hoist reeving, size, and type of wire rope for various equipment loads.

1926.1433(d)(1)(vi)

Recommended boom hoist reeving diagram, where applicable; size, type and length of wire rope.

1926.1433(d)(1)(vii) Tire Pressure (Where Applicable)

1926.1433(d)(1)(viii)

Caution or warnings relative to limitations on equipment and operating procedures, including an indication of the least stable direction.

1926.1433(d)(1)(x)

Instructions for boom erection and conditions under which the boom, or boom and jib combinations, may be raised or lowered.

1926.1433(d)(1)(xi)

Whether the hoist holding mechanism is automatically or manually controlled, whether free fall is available, or any combination of these.

1926.1433(d)(1)(xii)

The maximum telescopic travel length of each boom telescopic section.

1926.1433(d)(1)(xiii)

Whether sections are telescoped manually or with power.

1926.1433(d)(1)(xiv)

The sequence and procedure for extending and retracting the telescopic boom section.

1926.1433(d)(1)(xv)

Maximum loads permitted during the boom extending operation, and any limiting conditions or cautions.

1926.1433(d)(1)(xvi)

Hydraulic relief valve settings specified by the manufacturer.

1926.1433(d)(1)(ii)

A work area chart for which capacities are listed in the load chart. (Note: An example of this type of chart is in ASME B30.5-2004, section 5-1.1.3, Figure 11).

Related Code Sections


1926.1433(d)(1) Cranes & Derricks in Construction, Rated Capacity and Related Information
The information available in the cab ( see § 1926.1417(c)) regarding "rated capacity" and related information must include, at a minimum ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(1) Rated Capacity and Related Information
1926.1433(d)(1)(iv) Cranes & Derricks in Construction,
Recommended reeving for the hoist lines must be shown ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(1) Rated Capacity and Related Information > 1926.1433(d)(1)(iv)
1926.1433(d)(1)(ix) Cranes & Derricks in Construction,
Position of the gantry and requirements for intermediate boom suspension (where applicable ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(1) Rated Capacity and Related Information > 1926.1433(d)(1)(ix)
1926.1433(d)(1)(v) Cranes & Derricks in Construction,
Recommended parts of hoist reeving, size, and type of wire rope for various equipment loads ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(1) Rated Capacity and Related Information > 1926.1433(d)(1)(v)
1926.1433(d)(1)(vi) Cranes & Derricks in Construction,
Recommended boom hoist reeving diagram, where applicable; size, type and length of wire rope ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1433 Design, Construction and Testing > 1926.1433(d) > 1926.1433(d)(1) Rated Capacity and Related Information > 1926.1433(d)(1)(vi)
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE