1926.451(e)(5) Ramps and Walkways
Go To Full Code Chapter
1926.451(e)(5)(i)
Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part -- Fall Protection;
1926.451(e)(5)(ii)
No ramp or walkway shall be inclined more than a slope of one (1) vertical to three (3) horizontal (20 degrees above the horizontal).
1926.451(e)(5)(iii)
If the slope of a ramp or a walkway is steeper than one (1) vertical in eight (8) horizontal, the ramp or walkway shall have cleats not more than fourteen (14) inches (35 cm) apart which are securely fastened to the planks to provide footing.
Upcodes Diagrams
Related Code Sections
1926.451(e)(5) Scaffolds, Ramps and Walkways
Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part -- Fall Protection ...
1926.501(b)(6) Fall Protection, "Ramps, Runways, and Other Walkways"
Each employee on ramps, runways, and other walkways shall be protected from falling 6 feet (1.8 m) or more to lower levels by guardrail systems ...
1926.803(m)(2) Underground Construction, Caissons, Cofferdams and Compressed Air,
the length of all walkways on open sides in accordance with Subpart M of this part. Where walkways are ramped under safety screens, the walkway surface ...
1926.803(m) Underground Construction, Caissons, Cofferdams and Compressed Air, Bulkheads and Safety Screens
of this part. Where walkways are ramped under safety screens, the walkway surface shall be skidproofed by cleats or by equivalent means ...
1926.802(c) Underground Construction, Caissons, Cofferdams and Compressed Air,
Cofferdam walkways, bridges, or ramps with at least two means of rapid exit shall be provided with guardrails as specified in subpart M of this part ...