• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1114A.5 Ramp Height

California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1114A Exterior Ramps and Landings on Accessible Routes > 1114A.5 Ramp Height
JUMP TO FULL CODE CHAPTER

Ramps more than 30 inches (762 mm) above the adjacent floor or ground and open on one or both sides shall be provided with guardrails as required by Section 1013. Guardrails shall be continuous from the top of the ramp to the bottom of the ramp.

Related Code Sections


1114A.5 Housing Accessibility, Ramp Height
Ramps more than 30 inches (762 mm) above the adjacent floor or ground and open on one or both sides shall be provided with guardrails as required ...
California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1114A Exterior Ramps and Landings on Accessible Routes > 1114A.5 Ramp Height
1122A.4 Housing Accessibility, Ramp Height
Ramps more than 30 inches (762 mm) above the adjacent floor or ground and open on one or both sides shall be provided with a guard as required ...
California Building Code 2016 (Vol 1 & 2) > 11A Housing Accessibility > 1122A Interior Ramps and Landings on Accessible Routes > 1122A.4 Ramp Height
11B-505.4 Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing, Height
nosings, and ramp surfaces. Handrails shall be at a consistent height above walking surfaces, stair nosings, and ramp surfaces. FIGURE 11B -505.4 ...
California Building Code 2016 (Vol 1 & 2) > 11B Accessibility to Public Buildings, Public Accommodations, Commercial Buildings and Public Housing > 11B-505 Handrails > 11B-505.4 Height
R311.8.3.1 Building Planning, Height
Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm) ...
California Residential Code 2016 > 3 Building Planning > R311 Means of Egress > R311.8 Ramps > R311.8.3 Handrails Required > R311.8.3.1 Height
R311.8.3.1 Building Planning, Height
Handrail height, measured above the finished surface of the ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm) ...
California Residential Code 2019 > 3 Building Planning > R311 Means of Egress > R311.8 Ramps > R311.8.3 Handrails Required > R311.8.3.1 Height
Help Contact Us Privacy Terms
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE