• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

R609.4.1 Rake Beam

2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.4 Masonry Gables > R609.4.1 Rake Beam
JUMP TO FULL CODE CHAPTER

Where concrete or masonry is carried full height to the roof line, a cast-in-place rake beam as detailed in Figure R609.4.1 shall be provided. The minimum thickness of the rake beam from top of masonry shall be 4 inches (102 mm). One No. 5 continuous reinforcing bar shall be placed in the rake beam along the roof line.

FIGURE R609.4.1
CONTINUOUS GABLE ENDWALL REINFORCEMENT ONE AND MULTISTORY

Related Code Sections


R609.4.1 Wall Construction, Rake Beam
Where concrete or masonry is carried full height to the roof line, a cast-in-place rake beam as detailed in Figure R609.4.1 shall be provided. The ...
2014 FBC - Residential, 5th edition > 6 Wall Construction > R609 Grouted Masonry > R609.4 Masonry Gables > R609.4.1 Rake Beam
2121.2.3.6 Masonry,
A tie beam may follow the rake of a gable or shed end if the slope does not exceed 3:12 and the requirements of Sections 2121.2.1.2 and 2121.2.1.3 ...
2017 FBC - Building, 6th edition > 21 Masonry > 2121 High-Velocity Hurricane Zones— Construction Details > 2121.2 Exterior Walls > 2121.2.3 Tie Beams > 2121.2.3.6
2121.2.3.6 Masonry,
A tie beam may follow the rake of a gable or shed end if the slope does not exceed 3:12 and the requirements of Sections 2121.2.1.2 and 2121.2.1.3 ...
2014 FBC - Building, 5th edition > 21 Masonry > 2121 High-Velocity Hurricane Zones— Construction Details > 2121.2 Exterior Walls > 2121.2.3 Tie Beams > 2121.2.3.6
2121.2.3.6 Masonry,
A tie beam may follow the rake of a gable or shed end if the slope does not exceed 3:12 and the requirements of Sections 2121.2.1.2 and 2121.2.1.3 ...
2020 FBC - Building, 7th edition > 21 Masonry > 2113 Masonry Chimneys > 2121 High-Velocity Hurricane Zones—Construction Details > 2121.2 Exterior Walls > 2121.2.3 Tie Beams > 2121.2.3.6
2121.2.3 Masonry, Tie Beams
A tie beam of reinforced concrete shall be placed in all walls of unit masonry, at each floor or roof level, and at such intermediate levels as may ...
2020 FBC - Building, 7th edition > 21 Masonry > 2113 Masonry Chimneys > 2121 High-Velocity Hurricane Zones—Construction Details > 2121.2 Exterior Walls > 2121.2.3 Tie Beams
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE