1101.13.1 Rain Leaders and Conductors
Go To Full Code Chapter
Rain leaders and conductors connected to a building storm sewer shall have a cleanout installed at the base of the outside leader or outside conductor before it connects to the horizontal drain.
Upcodes Diagrams
Related Code Sections
1101.13.1 Storm Drainage, Rain Leaders and Conductors
Rain leaders and conductors connected to a building storm sewer shall have a cleanout installed at the base of the outside leader or outside ...
1103.1 Storm Drainage, Vertical Conductors and Leaders
Vertical conductors and leaders shall be sized by the maximum projected roof area and Table 1103.1.
TABLE 1103.1 SIZING ROOF DRAINS, LEADERS ...
K 106.4 Potable Rainwater Catchment Systems, Drains, Conductors, and Leaders
The design and size of rainwater drains, conductors, and leaders shall comply with this code ...
1101.4.3 Storm Drainage, Leaders
Leaders installed outside shall comply with the applicable standards referenced in Table 701.2 for aboveground drain, waste, and vent pipe; aluminum ...