1926.1435(e)(5)(vii) Rail Travel Limiting Device
JUMP TO FULL CODE CHAPTER
The travel distance in each direction must be limited to prevent the travel bogies from running into the end stops or buffers. Temporary alternative measures: A spotter who is in direct communication with the operator must be used when operations are conducted within 10 feet of either end of the travel rail end stops; the spotter must inform the operator of the distance of the travel bogies from the end stops or buffers.
Related Code Sections
1926.1435(e)(5)(vii) Cranes & Derricks in Construction, Rail Travel Limiting Device
The travel distance in each direction must be limited to prevent the travel bogies from running into the end stops or buffers. Temporary alternative ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1435 Tower Cranes > 1926.1435(e) Operational Aids > 1926.1435(e)(5) Category I Operational Aids and Alternative Measures > 1926.1435(e)(5)(vii) Rail Travel Limiting Device
1926.1435(e)(5)(i) Cranes & Derricks in Construction, Trolley Travel Limiting Device
The travel of the trolley must be restricted at both ends of the jib by a trolley travel limiting device to prevent the trolley from running ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1435 Tower Cranes > 1926.1435(e) Operational Aids > 1926.1435(e)(5) Category I Operational Aids and Alternative Measures > 1926.1435(e)(5)(i) Trolley Travel Limiting Device
1926.1435(e)(5) Cranes & Derricks in Construction, Category I Operational Aids and Alternative Measures
The travel of the trolley must be restricted at both ends of the jib by a trolley travel limiting device to prevent the trolley from ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1435 Tower Cranes > 1926.1435(e) Operational Aids > 1926.1435(e)(5) Category I Operational Aids and Alternative Measures
1926.1435(e)(6)(ii) Cranes & Derricks in Construction, Trolley Travel Deceleration Device
employer must post a notice in the cab of the crane notifying the operator that the trolley travel deceleration device is malfunctioning ...
OSHA 1926 Construction > CC Cranes & Derricks in Construction > 1926.1435 Tower Cranes > 1926.1435(e) Operational Aids > 1926.1435(e)(6) Category II Operational Aids and Alternative Measures > 1926.1435(e)(6)(ii) Trolley Travel Deceleration Device
1926.606(e) Motor Vehicles, Mechanized Equipment, and Marine Operations, Rail
for the purpose of 1926.605, means a light structure serving as a guard at the outer edge of a ship's deck ...
OSHA 1926 Construction > O Motor Vehicles, Mechanized Equipment, and Marine Operations > 1926.606 Definitions Applicable to This Subpart > 1926.606(e) Rail