// CODE SNIPPET
810.5 Rail Platforms
JUMP TO FULL CODE CHAPTER
Rail platforms shall comply with 810.5.
Rail platforms shall not exceed a slope of 1:48 in all directions.
EXCEPTION: Where platforms serve vehicles operating on existing track or track laid in existing roadway, the slope of the platform parallel to the track shall be permitted to be equal to the slope (grade) of the roadway or existing track.
Platform boarding edges not protected by platform screens or guards shall have detectable warnings complying with 705 along the full length of the public use area of the platform.
Station platforms shall be positioned to coordinate with vehicles in accordance with the applicable requirements of 36 CFR Part 1192. Low-level platforms shall be 8 inches (205 mm) minimum above top of rail.
EXCEPTION: Where vehicles are boarded from sidewalks or street-level, low-level platforms shall be permitted to be less than 8 inches (205 mm).
Note to Reader: The Department of Transportation's ADA standards note permitted alternatives where compliance is not operationally or structurally feasible in light rail, commuter rail, or intercity rail systems:
810.5.3 Platform and Vehicle Floor Coordination. Station platforms shall be positioned to coordinate with vehicles in accordance with the applicable requirements of 36 CFR part 1192. Low-level platforms shall be 8 inches (205 mm) minimum above top of rail. In light rail, commuter rail, and intercity rail systems where it is not operationally or structurally feasible to meet the horizontal gap or vertical difference requirements of part 1192 or 49 CFR part 38, mini-high platforms, car-borne or platform-mounted lifts, ramps or bridge plates or similarly manually deployed devices, meeting the requirements of 49 CFR part 38, shall suffice.
EXCEPTION: Where vehicles are boarded from sidewalks or street- level, low-level platforms shall be permitted to be less than 8 inches (205 mm).
Advisory 810.5.3 Platform and Vehicle Floor Coordination. The height and position of a platform must be coordinated with the floor of the vehicles it serves to minimize the vertical and horizontal gaps, in accordance with the ADA Accessibility Guidelines for Transportation Vehicles (36 CFR Part 1192). The vehicle guidelines, divided by bus, van, light rail, rapid rail, commuter rail, intercity rail, are available at www.access-board.gov. The preferred alignment is a high platform, level with the vehicle floor. In some cases, the vehicle guidelines permit use of a low platform in conjunction with a lift or ramp. Most such low platforms must have a minimum height of eight inches above the top of the rail. Some vehicles are designed to be boarded from a street or the sidewalk along the street and the exception permits such boarding areas to be less than eight inches high.
Related Code Sections
810.5 Special Rooms, Spaces, and Elements, Rail Platforms
Rail platforms shall comply with 810.5. Rail ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 810 Transportation Facilities > 810.5 Rail Platforms
206.4.4.2 Scoping Requirements, Direct Connections
Direct connections to other facilities shall provide an accessible route complying with 404 from the point of connection to boarding platforms ...
2010 ADA Standards > 2 Scoping Requirements > 206 Accessible Routes > 206.4 Entrances > 206.4.4 Transportation Facilities > 206.4.4.2 Direct Connections
810.6 Special Rooms, Spaces, and Elements, Rail Station Signs
Rail station signs shall comply with 810.6.
EXCEPTION . Signs shall not be required to comply with 810.6.1 and 810.6.2 where audible signs ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 810 Transportation Facilities > 810.6 Rail Station Signs
810.6.2 Special Rooms, Spaces, and Elements, Routes and Destinations
Lists of stations, routes and destinations served by the station which are located on boarding areas, platforms, or mezzanines shall comply ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 810 Transportation Facilities > 810.6 Rail Station Signs > 810.6.2 Routes and Destinations
206.4 Scoping Requirements, Entrances
intercity rail stations retrofitted in accordance with 49 CFR 37.49 or 49 CFR 37.51 shall not be required to comply with 206.4.4.1 ...