R802.11.1.2 Rafter Uplift Resistance
JUMP TO FULL CODE CHAPTER
Individual rafters shall be attached to supporting wall assemblies by connections capable of resisting uplift forces as determined by Table R802.11 or as determined by accepted engineering practice. Connections for beams used in a roof system shall be designed in accordance with accepted engineering practice.
Related Code Sections
R802.11.1.2 Roof-Ceiling Construction, Rafter Uplift Resistance
Individual rafters shall be attached to supporting wall assemblies by connections capable of resisting uplift forces as determined by Table R802.11 ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 8 Roof-Ceiling Construction > R802 Wood Roof Framing > R802.11 Roof Tie-Down > R802.11.1 Uplift Resistance > R802.11.1.2 Rafter Uplift Resistance
2308.7.5 Wood, Wind Uplift
The roof construction shall have rafter and truss ties to the wall below. Resultant uplift loads shall be transferred to the foundation using ...
Building Code of the Texas Industrialized Housing and Buildings Program > 23 Wood > 2308 Conventional Light-Frame Construction > 2308.7 Roof and Ceiling Framing > 2308.7.5 Wind Uplift
R602.3.5 Wall Construction, Braced Wall Panel Uplift Load Path
and fasteners designed to resist combined uplift and shear forces in accordance with accepted engineering practice.
...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 6 Wall Construction > R602 Wood Wall Framing > R602.3 Design and Construction > R602.3.5 Braced Wall Panel Uplift Load Path
R504.1.3 Floors, Uplift and Buckling
Where required, resistance to uplift or restraint against buckling shall be provided by interior bearing walls or properly designed stub walls ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > 5 Floors > R504 Pressure Preservative-Treated Wood Floors (On Ground) > R504.1 General > R504.1.3 Uplift and Buckling
AS106.14 Strawbale Construction, Resistance to Wind Uplift Forces
Plaster mesh in skins of strawbale walls that resist uplift forces from the roof assembly, as determined in accordance with Section R802.11, shall ...
Residential Code for one- and two-family dwellings of the Texas Industrialized Housing and Buildings Program > S Strawbale Construction > AS106 Strawbale Walls — Structural > AS106.14 Resistance to Wind Uplift Forces