• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3108 Radio and Television Towers

2010 Building Code of NY > 31 Special Construction > 3108 Radio and Television Towers
JUMP TO FULL CODE CHAPTER

3108.1 General

Subject to the provisions of Chapter 16 and the requirements of Chapter 15 governing the fire-resistance ratings of buildings for the support of roof structures, radio and television towers shall be designed and constructed as herein provided.

3108.2 Location and Access

Towers shall be located and equipped with step bolts and ladders so as to provide ready access for inspection purposes. Guy wires or other accessories shall not cross or encroach upon any street or other public space, or over above-ground electric utility lines, or encroach upon any privately owned property without written consent of the owner of the encroached-upon property, space or above-ground electric utility lines.

3108.3 Construction

Towers shall be constructed of approved corrosion-resistant noncombustible material. The minimum type of construction of isolated radio towers not more than 100 feet (30 480 mm) in height shall be Type IIB.

3108.4 Loads

Towers shall be designed to resist wind loads in accordance with TIA/EIA-222. Consideration shall be given to conditions involving wind load on ice-covered sections in localities subject to sustained freezing temperatures.

3108.4.1 Dead Load

Towers shall be designed for the dead load plus the ice load in regions where ice formation occurs.

3108.4.2 Wind Load

Adequate foundations and anchorage shall be provided to resist two times the calculated wind load.

3108.5 Grounding

Towers shall be permanently and effectively grounded.

Related Code Sections


Section 3108 Special Construction, Radio and Television Towers
structures, radio and television towers shall be designed and constructed as herein provided ...
2010 Building Code of NY > 31 Special Construction > 3108 Radio and Television Towers
3108.4.1 Special Construction, Dead Load
Towers shall be designed for the dead load plus the ice load in regions where ice formation occurs ...
2010 Building Code of NY > 31 Special Construction > 3108 Radio and Television Towers > 3108.4 Loads > 3108.4.1 Dead Load
3108.4.2 Special Construction, Wind Load
Adequate foundations and anchorage shall be provided to resist two times the calculated wind load ...
2010 Building Code of NY > 31 Special Construction > 3108 Radio and Television Towers > 3108.4 Loads > 3108.4.2 Wind Load
101.2 General Requirements, Scope
and television transmission, communication and wind generation towers not attached to buildings.  ...
2010 Building Code of NY > 1 General Requirements > 101 Title, Scope and Purpose > 101.2 Scope
(B) Special Equipment, Communications Systems
Communications, radio, and television coaxial cables within the scope of Articles 800 through 820 shall be permitted at a height of not less than 3.0 ...
National Electrical Code, 2017 > 6 Special Equipment > 680 Swimming Pools, Fountains, and Similar Installations > 680.9 Overhead Conductor Clearances > (B) Communications Systems
Help Contact Us Privacy Terms
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
View thousands of relevant UL Certified products and assemblies that help achieve code compliance
Access to UL product and system certification information.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
Join the waitlist
We are looking to gauge the level of interest in linking UL product and system certification information alongside related code sections.

Let us know your email and we’ll ping you once it’s ready! Learn more.

Thank you for your interest!

If you’re open to it, we would love to jump on the phone to make sure we’re building this in the best way possible for your workflow. Any insight or advice would be greatly appreciated. We’ve sent you an email with a calendar link to book at time with us.


Cancel
Get Early Access
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE