• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1224.34.3.1 Radiation Therapy Space

California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.34 Nuclear Medicine > 1224.34.3 Radiotherapy Service Space > 1224.34.3.1 Radiation Therapy Space
JUMP TO FULL CODE CHAPTER
If radiation therapy is provided, the following shall be accommodated:
  1. Patient reception and waiting areas.
  2. Space for medical and physics staff functions.
  3. Space for equipment and supplies.
  4. Housekeeping room.
  5. Direct access to space provided for radiation measurement and calibration equipment, including a calibration constancy instrument and access to a secondary standard dose meter.
    1. 5.1. A megavoltage treatment unit capable of delivering x-rays or gamma rays of effective energy 500 KeV or more and conforming to the requirements of Chapter 31C and the California Radiation Control Regulations, California Code of Regulations, Title 17, Division 1, Chapter 5, Subchapter 4.
    2. 5.2. Access to a medium voltage or superficial treatment unit delivering 500 KeV or less, but otherwise having the same functional characteristics as the above mega-voltage units and conforming to the requirements of Chapter 31C and the California Radiation Control Regulations, California Code of Regulations, Title 17, Division 1, Chapter 5, Subchapter 4.
    3. 5.3. Direct access to space provided for brachytherapy equipment which shall meet the requirements of Chapter 31C and the California Radiation Control Regulations, California Code of Regulations, Title 17, Division 1, Chapter 5, Subchapter 4.
    4. 5.4. Shielding of the rooms shall meet the requirements of Chapter 31C and the California Radiation Control Regulations. California Code of Regulations, Title 17, Division 1, Chapter 5, Subchapter 4.

Related Code Sections


1224.34.3.1 Interior Environment, Radiation Therapy Space
If radiation therapy is provided, the following shall be accommodated: Patient reception and waiting areas. Space for medical and physics staff ...
California Building Code 2016 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.34 Nuclear Medicine > 1224.34.3 Radiotherapy Service Space > 1224.34.3.1 Radiation Therapy Space
1224.34.3.1 Interior Environment, Radiation Therapy Space
If radiation therapy is provided, the following shall be accommodated: Patient reception and waiting areas. Space for medical ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.34 Nuclear Medicine > 1224.34.3 Radiotherapy Service Space > 1224.34.3.1 Radiation Therapy Space
1224.34.3 Interior Environment, Radiotherapy Service Space
If radiation therapy is provided, the following shall be accommodated: Patient reception and waiting areas. Space for medical ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.34 Nuclear Medicine > 1224.34.3 Radiotherapy Service Space
3104C.5 [DPH] Radiation,
A flashing red warning signal light energized only when the useful beam is on shall be located adjacent to the entrance(s) to a therapy room ...
California Building Code 2019 (Vol 1 & 2) > 31C [DPH] Radiation > 3104C Medical Therapeutic X-Ray Installations > 3104C.5
1224.28.6 Interior Environment, Electroconvulsive Therapy
If electroconvulsive therapy (ECT) is provided, the requirements of this section shall be met. Where a psychiatric unit is part of a general acute ...
California Building Code 2019 (Vol 1 & 2) > 12 Interior Environment > 1224 [OSHPD 1] Hospitals > 1224.28 Supplemental Surgery and Special Procedure Services > 1224.28.6 Electroconvulsive Therapy
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING