• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Suggested code sections
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1213.2 Radiant Floor Heating Panels

Los Angeles Mechanical Code > 12 Hydronics > 1213.0 System Controls > 1213.2 Radiant Floor Heating Panels
JUMP TO FULL CODE CHAPTER
Radiant floor heating panels shall be protected with a high-limit control set 20°F (11°C) above the maximum design water temperature for the panel to prevent the introduction of heat into the panel. The high-limit setting shall not exceed the temperature rating for the pipe and shall be equipped with a manual reset.

Related Code Sections


1213.2 Hydronics, Radiant Floor Heating Panels
Radiant floor heating panels shall be protected with a high-limit control set 20°F (11°C) above the maximum design water temperature for the panel ...
Los Angeles Mechanical Code > 12 Hydronics > 1213.0 System Controls > 1213.2 Radiant Floor Heating Panels
1217.2 Hydronics, Radiant Under-Floor Heating
    The radiant heating panel temperature shall not exceed the maximum temperature rating of the materials used in the construction ...
Los Angeles Mechanical Code > 12 Hydronics > 1217.0 Radiant Heating and Cooling > 1217.2 Radiant Under-Floor Heating
1217.0 Hydronics, Radiant Heating and Cooling
Radiant heating and cooling panels shall be installed in accordance ...
Los Angeles Mechanical Code > 12 Hydronics > 1217.0 Radiant Heating and Cooling
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE