// CODE SNIPPET
3306.2.2 Quantity Restrictions
JUMP TO FULL CODE CHAPTER
It shall be unlawful to store small arms ammunition and primers, powder-actuated tool loads, black powder or smokeless propellants in quantities exceeding the following:
- Three hundred thousand loaded shells containing shot for shotguns not exceeding No. 8 gauge;
- One million cartridges for pistols and powder-actuated tool loads;
- Five hundred thousand cartridges for rifles of a caliber not larger than 0.45 inch (11.4 mm);
- Ten thousand cartridges for rifles of a caliber not larger than 1/2 inch (12.7 mm);
- Five thousand cartridges for rifles of a caliber between 1/2 inch (12.7 mm) and 0.58 inch (14.7 mm);
- Five thousand blank cartridges of a caliber not larger than 0.45 inch (11.4 mm);
- Three million primers for central fire ammunition;
- Six million percussion caps, or primers, without anvils;
- Fifty pounds (23 kg) aggregate of black powder or smokeless propellant;
- Any storage in excess of the amounts authorized by permit.
Related Code Sections
1104.3 Refrigeration, Refrigerant Restrictions
Refrigerant applications, maximum quantities and use shall be restricted in accordance with Sections 1104.3.1 through 1104.3.4 ...
NYC Mechanical Code 2008 > 11 Refrigeration > 1104 System Application Requirements > 1104.3 Refrigerant Restrictions
1104.3 Refrigeration, Refrigerant Restrictions
Refrigerant applications, maximum quantities and use shall be restricted in accordance with Sections 1104.3.1 through 1104.3.3 ...
NYC Mechanical Code 2022 > 11 Refrigeration > 1104 System Application Requirements > 1104.3 Refrigerant Restrictions
1104.3 Refrigeration, Refrigerant Restrictions
Refrigerant applications, maximum quantities and use shall be restricted in accordance with Sections 1104.3.1 through 1104.3.3 ...
NYC Mechanical Code 2014 > 11 Refrigeration > 1104 System Application Requirements > 1104.3 Refrigerant Restrictions
Article 5 Occupancy and Construction Classification, Occupancy Group C-Mercantile
inspection. Highly combustible or flammable goods, such as those made of pyroxylin products, shall be limited to small quantities that do not constitute ...
NYC 1968 Code (Vol I) > 3 Occupancy and Construction Classification > 5 Occupancy Group C-Mercantile
*§28-421.3 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work, Restriction
Each elevator agency director shall supervise and perform elevator work or inspections and tests pursuant to article 304 of chapter 3 of this code ...
NYC General Admin. Provisions 2022 > 4 Licensing and Registration of Businesses, Trades and Occupations Engaged in Building Work > *421 Elevator Inspection Agency Director License > *§28-421.3 Restriction