4106.1 Pyrophoric Materials Classified as a Class IV Material
JUMP TO FULL CODE CHAPTER
Pyrophoric materials classified as a Class IV material as defined in Section 42-272 of the Zoning Resolution may be utilized in manufacturing processes or other production in manufacturing districts only when authorized by a special permit pursuant to Section 42-276 of the Zoning Resolution.
It shall be unlawful to manufacture pyrophoric materials classified as a Class IV material as defined in Section 42-272 of the Zoning Resolution.
It shall be unlawful to store pyrophoric materials classified as a Class IV material as defined in Section 42-272 of the Zoning Resolution, except accessory storage authorized by a special permit pursuant to Section 42-276 of the Zoning Resolution.
Related Code Sections
2702.2.12 Electrical, Pyrophoric Materials
Emergency power shall be provided for occupancies with silane gas in accordance with the New York City Fire Code ...
NYC Building Code 2008 > 27 Electrical > 2702 Emergency and Standby Power Systems > 2702.2 Where Required > 2702.2.12 Pyrophoric Materials
2702.2.12 Electrical, Pyrophoric Materials
Emergency power shall be provided for occupancies with silane gas in accordance with the New York City Fire Code ...
NYC Building Code 2014 > 27 Electrical > 2702 Emergency and Standby Power Systems > 2702.2 Where Required > 2702.2.12 Pyrophoric Materials
419.7.6 Special Detailed Requirements Based on Use and Occupancy, Pyrophoric Material
The total quantity of solid or liquid pyrophoric material allowed within a laboratory unit, excluding any quantities in a storage room, shall ...
NYC Building Code 2008 > 4 Special Detailed Requirements Based on Use and Occupancy > 419 Non-Production Chemical Laboratories > 419.7 Quantity Limitations > 419.7.6 Pyrophoric Material
424.7.6 Special Detailed Requirements Based on Use and Occupancy, Pyrophoric Material
The total quantity of solid or liquid pyrophoric material allowed within a laboratory unit, excluding any quantities in a storage room, shall ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 424 Nonproduction Chemical Laboratories > 424.7 Quantity Limitations > 424.7.6 Pyrophoric Material
307.3 Use and Occupancy Classification, High-Hazard Group H-1
, unclassified detonable Oxidizers, Class 4 Unstable (reactive) materials, Class 3 detonable and Class 4 Pyrophoric materials, detonable ...
NYC Building Code 2014 > 3 Use and Occupancy Classification > 307 High-Hazard Group H > 307.3 High-Hazard Group H-1