• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

[F] 902.1 Pump and Riser Room Size

Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size
JUMP TO FULL CODE CHAPTER
ILLUSTRATION
Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary for the installation, as defined by the manufacturer, with sufficient working room around the stationary equipment. Clearances around equipment to elements of permanent construction, including other installed equipment and appliances, shall be sufficient to allow inspection, service, repair or replacement without removing such elements of permanent construction or disabling the function of a required fire-resistance-rated assembly. Fire pump and automatic sprinkler system riser rooms shall be provided with doors and unobstructed passageways large enough to allow removal of the largest piece of equipment.

[F] 902.1.1 Access

Automatic sprinkler system risers, fire pumps and controllers shall be provided with ready access. Where located in a fire pump room or automatic sprinkler system riser room, the door shall be permitted to be locked provided that the key is available at all times.

[F] 902.1.2 Marking on Access Doors

Access doors for automatic sprinkler system riser rooms and fire pump rooms shall be labeled with an approved sign. The lettering shall be in contrasting color to the background. Letters shall have a minimum height of 2 inches (51 mm) with a minimum stroke of 3/8 inch (10 mm).

[F] 902.1.3 Environment

Automatic sprinkler system riser rooms and fire pump rooms shall be maintained at a temperature of not less than 40°F (4°C). Heating units shall be permanently installed.

[F] 902.1.4 Lighting

Permanently installed artificial illumination shall be provided in the automatic sprinkler system riser rooms and fire pump rooms.

Related Code Sections


902.1 Fire Protection and Life Safety Systems, Pump and Riser Room Size
Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size
902.1 Fire Protection and Life Safety Systems, Pump and Riser Room Size
Where provided, fire pump rooms and automatic sprinkler system riser rooms shall be designed with adequate space for all equipment necessary ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size
902.1.3 Fire Protection and Life Safety Systems, Environment
Automatic sprinkler system riser rooms and fire pump rooms shall be maintained at a temperature of not less than 40°F (4°C). Heating units shall ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size > 902.1.3 Environment
902.1.1 Fire Protection and Life Safety Systems, Access
Automatic sprinkler system risers, fire pumps and controllers shall be provided with ready access. Where located in a fire pump room or automatic ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size > 902.1.1 Access
902.1.1 Fire Protection and Life Safety Systems, Access
Automatic sprinkler system risers, fire pumps and controllers shall be provided with ready access. Where located in a fire pump room or automatic ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 902 Fire Pump and Riser Room Size > 902.1 Pump and Riser Room Size > 902.1.1 Access
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING